Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: LCBB INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LCBB INC. in 3265 BABCOCK BOULEVARD, PITTSBURGH, PA 15237 (NAICS 811111). OSHA activity number 342936598.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lcbb INC. for free Get an email when a new federal OSHA severe-injury report for Lcbb INC. is published. One employer, no account, unsubscribe in one click.
Establishment
LCBB INC.
Site address
3265 BABCOCK BOULEVARD
City
PITTSBURGH
State
PA
ZIP
15237
Mailing
3265 BABCOCK BOULEVARD, PITTSBURGH, PA 15237
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 21, 2018
Abate by
Mar 19, 2018
Penalty
Initial $0 · Current $0
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees from potential struck by and/or crushing hazards from falling loads and/or lift parts:  (a) Facility, 3265 Babcock Boulevard, Pittsburgh, PA:  On or about February 8, 2018 the employer did not ensure that the operator(s) ceased operations of the Ammco drive on 12000 lb. capacity automotive lift, Model LMT-12, Serial No. P00000720, when it had been determined that there were broken components in the locking devices.  There was a broken rod in the drive system for the locking devices and one lock did not function properly.  The employees used a screw driver to jimmy the lock to secure or release it during use.  The lift had not been taken out of service until repairs could be made.
Recent events (1)
  • · Z (S) $0

1910.242 A

Other-than-serious 1 instance 2 exposed
Issued
Feb 21, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition:  (a) Facility, 3265 Babcock Boulevard, Pittsburgh, PA:  On or about February 8, 2018 an airline set to 125 psi was used to supply pneumatic tools and had bubbles and holes and the air was leaking thereby not being kept in a safe condition.