HARAHAN, LA —
OSHA Inspection: UNISTAR PLASTICS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNISTAR PLASTICS LLC in 1420 SAMS AVE, STE E, HARAHAN, LA 70123 (NAICS 326199). OSHA activity number 342936655.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNISTAR PLASTICS LLC
- Site address
- 1420 SAMS AVE, STE E
- City
- HARAHAN
- State
- LA
- ZIP
- 70123
- Mailing
- 5821 CITRUS BLVD, STE B, HARAHAN, LA 70123
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 60
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- May 1, 2018
- Penalty
- Initial $6,984 · Current $4,190 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about 2/8/18 in the Extrusion and Bag Cutting Departments; the employer allowed employees to perform lockout on the Printer machines (19), the Bag-Cutting machines (14) and the COSMO bag-cutting machine (1) without having machine-specific lockout procedures.
Recent events (2)
- — I (S) $4190.4
- — Z (S) $6984
1910.147 C06 II
- Issued
- May 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection. On or about 2/8/18 in the Extrusion and Bag Cutting Departments; the employer allowed employees to perform lockout on the Printer machines (19), the Bag-Cutting machines (14) and the COSMO bag-cutting machine (1) without having any documentation of the periodic inspections conducted by the employer.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 IV
- Issued
- May 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date. On or about 2/8/18 in the Extrusion and Bag Cutting Departments; the employer allowed employees to perform lockout on the Printer machines (19), the Bag-Cutting machines (14) and the COSMO bag-cutting machine (1) without having any documentation of their receiving machine lockout training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Unistar Plastics LLC
View Unistar Plastics LLC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342936655.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.