Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AKROTEX, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of AKROTEX, INC. in 1804 AUSTIN STREET, ORANGE, TX 77630 (NAICS 325211). OSHA activity number 342940376.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Akrotex, INC. — free Get an email when a new federal OSHA severe-injury report for Akrotex, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AKROTEX, INC.
Site address
1804 AUSTIN STREET
City
ORANGE
State
TX
ZIP
77630
Mailing
1804 AUSTIN STREET, ORANGE, TX 77630
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
43
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II

Other-than-serious 1 instance 2 exposed
Issued
Jul 5, 2018
Abate by
Aug 9, 2018
Penalty
Initial $5,174 · Current $5,174
29 CFR 1910.147(c)(4)(ii): The Lock out/Tag procedure did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance.         On or about February 8, 2018, and times prior thereto, the employer did not ensure that the energy control procedures clearly and specifically outline the techniques to be utilized for the control of hazardous energy, when performing the servicing and maintenance activities on Egan Extruder machine.
Recent events (2)
  • — I (O) $5174
  • — Z (S) $5174

1910.147 D03

Other-than-serious 1 instance 2 exposed
Issued
Jul 5, 2018
Abate by
Aug 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source.       On or about February 8, 2018, and times prior thereto, the employer failed to ensure that the isolating devices needed to control the hazardous energy for Egan extruder machine were applied to isolate the equipment from the hydraulic energy, water and air.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 5, 2018
Abate by
Aug 9, 2018
Penalty
Initial $9,054 · Current $9,054
29 CFR 1910.212(a)(3)(ii): Point of operation of machinery was not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle.                                                                                                                In The Alternative       29 CFR 1910.28(b)(6)(i): Each employee less than 4 feet (1.2 m) above dangerous equipment was not protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system, unless the equipment was covered or guarded to eliminate the hazard.       On or about February 8, 2018, and times prior thereto, the employer failed to provide machine guards and/or guardrail system to prevent employees that were feeding plastic film into the EGAN extruder from having any part of their body in the danger zone where there were rotating parts and/or a moving screw.
Recent events (2)
  • — I (S) $9054
  • — Z (S) $9054

1910.28 B01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 5, 2018
Abate by
Aug 9, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1910.28(b)(1)(i):  The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by Guard rail systems, safety net systems or Personal fall arrest system.         On or about February 8, 2018, at the Akrotex, Inc, Orange Texas location, the employer did not protect employees from a 5 foot 4 inches fall hazard, while working from an elevated platform and feeding a plastic film into an EGAN extruder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9054

1910.1030 G02 II A

Other-than-serious 1 instance 2 exposed
Issued
Jul 5, 2018
Abate by
Aug 9, 2018
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1910.1030(g)(2)(ii)(A): The employer did not train each employee at the time of the initial assignment to tasks where occupational exposure to the biohazards could take place.       On or about February 15, 2018, the employer did not provide blood borne pathogens training to employees, who were exposed to blood and other potentially infectious materials while disassembled the Egan extruder machine for biohazard cleaning.