DAVIE, FL —
OSHA Inspection: GLOBAL PROTECTION PRODUCTS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GLOBAL PROTECTION PRODUCTS, LLC in 4800 SW 51ST ST SUITE 100, DAVIE, FL 33314 (NAICS 332321). OSHA activity number 342941424.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLOBAL PROTECTION PRODUCTS, LLC
- Site address
- 4800 SW 51ST ST SUITE 100
- City
- DAVIE
- State
- FL
- ZIP
- 33314
- Mailing
- 4800 SW 51ST ST SUITE 100, DAVIE, FL 33314
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 25
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.212 A03 II
- Issued
- Feb 14, 2018
- Abate by
- Mar 1, 2018
- Penalty
- Initial $6,468 · Current $6,468
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about February 12, 2018, at the manufacturing area of the above addressed worksite, employees were exposed to a caught by hazard while working with a drill press (i.e. Jet, Model No. JDP-17MF) that lacked point of operation guarding. b. On or about February 12, 2018, at the manufacturing area of the above addressed worksite, employees were exposed to a caught by hazard while working with a drill press (i.e. Powermatic, Model No. 2000, Serial No. 020900019) that lacked point of operation guarding. c. On or about February 12, 2018, at the manufacturing area of the above addressed worksite, employees were exposed to a caught by hazard while working with a roll forming machine (i.e. aluminum panels, 24 gauge) that lacked a point of operation guard on its cutting area.
Recent events (1)
- — Z (S) $6468
1910.212 B
- Issued
- Feb 14, 2018
- Penalty
- Initial $3,299 · Current $3,299
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: On or about February 12, 2018, at the manufacturing area of the above addressed worksite, employees were exposed to a struck by hazard while working with a drill press (i.e. Powermatic, Model No. 2000, Serial No. 020900019) that was not anchored.
Recent events (1)
- — Z (S) $3299
1910.217 B04 I
- Issued
- Feb 14, 2018
- Abate by
- Mar 1, 2018
- Penalty
- Initial $6,468 · Current $6,468
General-duty citation text
29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals: On or about February 12, 2018 at the manufacturing area of the above addressed worksite, an employee was exposed to a caught by hazard while working with a mechanical power press (i.e. Rouselle No. 3) whose pedal was not protected to prevent unintended operation.
Recent events (1)
- — Z (S) $6468
1910.217 C02 I A
- Issued
- Feb 14, 2018
- Abate by
- Mar 1, 2018
- Penalty
- Initial $6,468 · Current $6,468
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): On or about February 12, 2018 at the manufacturing area of the above addressed worksite, an employee was exposed to a caught by hazard while working with a mechanical power press (i.e. Rouselle No. 3) whose guard had openings at front, sides and over through which its point of operation could be accessed.
Recent events (1)
- — Z (S) $6468
1910.219 F03
- Issued
- Feb 14, 2018
- Penalty
- Initial $3,298 · Current $3,298
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: On or about February 12, 2018, at the manufacturing area the above addressed worksite, employees were exposed to a caught by hazard while working with a roll forming machine (i.e. aluminum panels, 24 gauge) which had sprocket wheels and chains which were not entirely enclosed.
Recent events (1)
- — Z (S) $3298
1910.305 B01 II
- Issued
- Feb 14, 2018
- Abate by
- Feb 22, 2018
- Penalty
- Initial $5,173 · Current $5,173
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about February 12, 2018, at the manufacturing area, of the above addressed worksite, an electrical panelboard (i.e. GE Power Mark Plus Load Center) installed inside a cabinet had an unused opening which was not covered, exposing employees to an electrical hazard.
Recent events (1)
- — Z (S) $5173
1910.303 G02 I
- Issued
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about February 12, 2018, at the manufacturing area of the above addressed worksite, a cabinet had energized electrical wires which were not guarded, exposing employees to an electrical fire hazard.
Recent events (1)
- — Z (O) $0
1910.305 G02 II
- Issued
- Feb 14, 2018
- Abate by
- Mar 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: On or about February 12, 2018, at the manufacturing area of the above addressed worksite, an electrical cord for a pedal of a grommet machine (i.e. Edward Segal Inc. Model No. 926) had a splice covered with electrical tape, exposing an employee to an electrical fire hazard.
Recent events (1)
- — Z (O) $0
More inspections at Global Protection Products, LLC
View Global Protection Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342941424.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.