LAKEWOOD, CO —
OSHA Inspection: HN INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HN INC. in 6801 W. COLFAX, LAKEWOOD, CO 80214 (NAICS 722513). OSHA activity number 342943784.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HN INC.
- Site address
- 6801 W. COLFAX
- City
- LAKEWOOD
- State
- CO
- ZIP
- 80214
- Mailing
- 6801 W. COLFAX, LAKEWOOD, CO 80214
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722513
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.36 D01
- Issued
- Jun 29, 2018
- Abate by
- Jul 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: (a) On or about February 12, 2018, and at times prior, employees were exposed to hazards that require immediate exit from the building such as fire and violence, in that the exit door at the back of the shop was locked. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.212 A03 II
- Issued
- Jun 29, 2018
- Abate by
- Jul 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) On or about February 12, 2018, and at times prior, employees were exposed to caught-in and laceration injuries when operating and working near the unguarded rotating dough hooks, wire whips, and beaters in the Hobart D-300 and A-200 mixers. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Jun 29, 2018
- Abate by
- Jul 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or about February 12, 2018, and at times prior, employees were exposed to short circuits, shock, and burns from a relocatable power tap which was plugged into an extension cord rather than into a wall. Also, it was permanently installed on the wall, such that tools would be required to remove it. The relocatable power tap was made available to recharge cell phones in the employee break area. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.304 B05
- Issued
- Jun 29, 2018
- Abate by
- Jul 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(5): A receptacle outlet was not installed wherever flexible cords with attachment plugs were used: (a) On or about February 12, 2018, and at times prior, employees were exposed to shock and burn hazards from the Hobart A-200 mixer that was plugged into an extension cord that was strung over a door frame, rather than plugging the mixer into a wall outlet. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Jun 29, 2018
- Abate by
- Jul 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) On or about February 12, 2018, and at times prior, employees were exposed to shock and burn hazards from an extension cord that was used as a permanent installation. The Hobart A-200 mixer was plugged into an extension cord for regular operations. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 722513)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342943784.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.