SYRACUSE, NY —
OSHA Inspection: GARDNER DENVER OBERDORFER PUMPS INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of GARDNER DENVER OBERDORFER PUMPS INC. in 5900 FIRESTONE DRIVE, SYRACUSE, NY 13206 (NAICS 333911). OSHA activity number 342944915.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARDNER DENVER OBERDORFER PUMPS INC.
- Site address
- 5900 FIRESTONE DRIVE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13206
- Mailing
- 5900 FIRESTONE DRIVE, SYRACUSE, NY 13206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333911
- Employees
- 27
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 II
- Issued
- Feb 23, 2018
- Abate by
- Mar 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer had not certified that periodic inspections of the energy control procedures had been performed: a) Throughout the facility, on or about 2/16/18: No certification that periodic inspections had been accomplished on the energy control procedures for employees performing servicing and/or maintenance on various equipment, including but limited to: CNC Machines; Ball Tester; Turret Lathe and Mazak Nexus 5000.
Recent events (1)
- — Z (O) $0
1910.303 F02
- Issued
- Feb 23, 2018
- Abate by
- Mar 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident a) Electrical Area, on or about 2/16/18: Electrical disconnect switches were not labeled as to what they controlled. b) Compressor Room, on or about 2/16/18: A electrical disconnect switch was not labeled as to what it controlled.
Recent events (1)
- — Z (O) $0
More inspections at Gardner Denver Oberdorfer Pumps INC.
View Gardner Denver Oberdorfer Pumps INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333911)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342944915.