CHICAGO, IL —
OSHA Inspection: LEMON X CORPORATION DBA BEVOLUTION GROUP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LEMON X CORPORATION DBA BEVOLUTION GROUP in 4401 S. OAKLEY AVE., CHICAGO, IL 60609 (NAICS 311421). OSHA activity number 342945185.
Where did this inspection happen?
- Establishment
- LEMON X CORPORATION DBA BEVOLUTION GROUP
- Site address
- 4401 S. OAKLEY AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60609
- Mailing
- 4401 S. OAKLEY AVE., CHICAGO, IL 60609
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311421
- Employees
- 55
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $11641.00 · Current $6985.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Production Area - On or about February 7, 2018, employees were required to operate the Liqui-Box C1000 Series Filler Machines on the C Line. The employer did not provide guarding to protect employees from coming in contact with the moving parts on these machines. Employees were thereby exposed to struck-by, caught-in and amputation hazards.
Recent events (2)
- — I (S) $6985
- — Z (S) $11641
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) Production Area - On or about February 13, 2018, authorized employees were required to perform maintenance and/or service on various equipment, such as Liqui-Box C1000 Series Filler Machines. The employer did not certify that periodic inspections of the energy control procedures were performed at least annually as required by the standard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 311421)
CHAMBERSBURG, PA—2026-07-08 00:00:00
KNOUSE FOODS COOPERATIVE, INC.
CHAMBERSBURG, PA—2026-07-08 00:00:00
KNOUSE FOODS COOPERATIVE, INC.
CHAMBERSBURG, PA—2026-07-08 00:00:00
KNOUSE FOODS COOPERATIVE, INC.
LUDINGTON, MI—2026-07-07 00:00:00
INDIAN SUMMER COOP
LUDINGTON, MI—2026-07-07 00:00:00
INDIAN SUMMER COOP
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342945185.