SAINT LOUIS, MO —
OSHA Inspection: COLLINS AND HERMANN
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COLLINS AND HERMANN in 10TH ST. & OLIVE ST., SAINT LOUIS, MO 63101 (NAICS 237130). OSHA activity number 342945458.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLLINS AND HERMANN
- Site address
- 10TH ST. & OLIVE ST.
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63101
- Mailing
- P.O. BOX 38901-0901, SAINT LOUIS, MO 63138
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 130
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.652 C01
- Issued
- Feb 26, 2018
- Penalty
- Initial $8,315 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(c)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): During duct bank construction at 10th St. and Olive, St. Louis, MO on 2-12-18, shoring was not installed in a protective manner. An employee was installing shoring in a 9.5 ft deep, 10 ft long trench where only one cylinder was in place at approximately three feet from the surface and between two sheeting panels.
Recent events (2)
- — I (S) $0
- — Z (S) $8315
1926.652 E01 II
- Issued
- Feb 26, 2018
- Penalty
- Initial $0 · Current $5,000
General-duty citation text
29 CFR 1926.652(e)(1)(ii): Support systems were not installed and removed in a manner that protected employees from cave-ins, structural collapses, or from being struck by members of the support system: During duct bank construction at 10th St. and Olive, St. Louis, MO on 2-12-18, shoring was not installed in a protective manner. An employee was installing shoring in a 9.5 ft deep, 10 ft long trench where only one cylinder was in place at approximately three feet from the surface and between two sheeting panels.
Recent events (2)
- — I (O) $5000
- — Z (S) $0
1926.651 K01
- Issued
- Feb 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins: During duct bank construction at 10th St. and Olive, St. Louis, MO on 2-12-18, shoring was not installed in a protective manner, by the employee considered to be the competent person. The employee was installing shoring in a 9.5 ft deep, 10 ft long trench where only one cylinder was in place at approximately three feet from the surface and between two sheeting panels.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Collins and Hermann
View Collins and Hermann's full OSHA safety record →
More inspections in this industry (NAICS 237130)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342945458.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.