Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLUID CONTROL SOLUTIONS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FLUID CONTROL SOLUTIONS, LLC in 75 NORTHWEST DRIVE, PLAINVILLE, CT 06062 (NAICS 332710). OSHA activity number 342948304.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fluid Control Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Fluid Control Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
75 NORTHWEST DRIVE
City
PLAINVILLE
State
CT
ZIP
06062
Mailing
75 NORTHWEST DRIVE, PLAINVILLE, CT 06062
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
25
Ownership type
A

10 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 10 instances 3 exposed
Issued
Mar 30, 2018
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:     Swiss Department, Tsugami Side:  On, or about, February 14, 2018, interlocks provided on the following CNC turning centers were broken or disabled:   A.  Machine 31, Tsugami. B.  Machine 33, Tsugami. C.  Methods Slant 50.   D.  Cincom L32. E.  Machines 37, 38 and 39, Tsugami.     F.  Machines 35 and 34, Tsugami BS 20-II.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

1910.212 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 30, 2018
Penalty
Initial $2,956 · Current $1,478 Reduced
29 CFR 1910.212(a)(4): Revolving drum(s), barrel(s), or container(s) were not guarded by enclosure(s) which were interlocked with the drive mechanism so that the barrel(s), drum(s), or container(s) could not revolve unless the enclosure(s) were in place:    Buffing/Tumbling Room:  On, or about, February 14, 2018, the tumbler used to process parts was not provided with an interlocked enclosure.
Recent events (2)
  • — I (S) $1478
  • — Z (S) $2956

1910.219 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:   Buffing/Tumbling Room:  On, or about, February 14, 2018, the chain and sprocket drive provided on the tumbler was not provided with a guard on the inside face.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 2 instances 5 exposed
Issued
Mar 30, 2018
Penalty
Initial $1,885 · Current $943 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    Swiss Department:  On, or about, February 14, 2018, compressed air nozzles used for cleaning at the following machines were measured to be greater than 30 p.s.i., dead-ended:  A.  Nozzle located between E19 and E20. B.   Nozzle located at E18.
Recent events (2)
  • — I (S) $942.5
  • — Z (S) $1885

1910.303 B07 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 30, 2018
Penalty
Initial $1,885 · Current $943 Reduced
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  Buffing/Tumbling Room:  On, or about, February 14, 2018, the armored cable provided to energize the Baldor buffing wheel was pulled from the fitting on the wall mounted junction box, exposing the coated conductors.
Recent events (2)
  • — I (S) $942.5
  • — Z (S) $1885

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   Buffing/Tumbling Room:  On, or about, February 14, 2018, the power cord provided on the tumbler was pulled from the fitting at the on/off box connection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 D01

Other-than-serious 1 instance 3 exposed
Issued
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces were inspected, regularly and as necessary, and maintained in a safe condition:   Swiss Department, Tsugami Side:  On, or about, February 14, 2018, the work area in front of Machine 31, a Tsugami CNC turning center, was slippery due to the presence of oil.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K06

Other-than-serious 1 instance 2 exposed
Issued
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  Buffing/Tumbling Room:  On, or about, February 14, 2018, employees who used HDX N95 filtering facepieces had not been provided with training regarding the proper use and limitations of the dust masks.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 G04

Other-than-serious 1 instance 6 exposed
Issued
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(4): Employees who have been designated to use fire fighting equipment as a part of the emergency action plan were not provided training in the use of appropriate equipment upon initial assignment and at least annually thereafter:    Plant:  On, or about, February 14, 2018, training had not been provided to employees who would be expected to use portable fire extinguishers.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 6 exposed
Issued
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    Swiss Department:  On, or about, February 14, 2018, several items were stored in front of two GE switchboard enclosures that housed the main disconnect switch and the buss duct distribution panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342948304.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.