Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EDGAR R. CUPIL GUZMAN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EDGAR R. CUPIL GUZMAN in 3922 CHAPMAN CHALMERS GATE, SMYRNA, GA 30080 (NAICS 238130). OSHA activity number 342949666.

Watch Edgar R. Cupil Guzman — free Get an email when a new federal OSHA severe-injury report for Edgar R. Cupil Guzman is published. One employer, no account, unsubscribe in one click.
Site address
3922 CHAPMAN CHALMERS GATE
City
SMYRNA
State
GA
ZIP
30080
Mailing
3374 AZTEC ROAD, APT. 36C, DORAVILLE, GA 30340
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2217.00 · Current $1330.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    (a) New residential construction on Lot #14, Top plate: On or about 02/14/2018, and at times prior, the employer exposed employees to overhead struck-by hazards, in that head protection was not provided to employees framing roof trusses which were placed onto the top plate by crane.
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1330.00 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    (a) New residential construction on Lot #14, Top plates: On or about 02/14/2018, and at times prior, the employer exposed employees to struck-by hazards while operating pneumatic nail guns, in that protective eyewear was not provided to employees operating pneumatic framing nail guns at 120 PSI.
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $3880.00 · Current $2328.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     (a) New residential construction located on Lot #14, Top plate front side: On or about 02/14/2018, and at times prior, the employer exposed employees to fall hazards of 21-feet, 3-inches to the lower level, in that a complete fall protection system was not used while engaged in roof truss installation.     (b) New residential construction located on Lot #14, Top plate rear side: On or about 02/14/2018, and at times prior, the employer exposed employees to fall hazards of 30-feet, 10-inches to the lower level, in that a fall protection system was not provided while engaged in roof truss installation.
Recent events (2)
  • — I (S) $2328.2
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2772.00 · Current $1663.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    (a) New residential construction located on Lot #14, First floor access to second level: On or about 02/14/2018, and at times prior, the employer exposed employees to fall hazards of up to 11-feet, 5-inches, in that the ladder used to access the upper level was not extended at least three feet or secured to the structure to allow access to both floors. The ladder used was extended 1-1/2 feet above the second level landing.
Recent events (2)
  • — I (S) $1663
  • — Z (S) $2772

1926.403 B01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employee:  (a) New residential construction located on Lot #14, Temporary electrical service box on front side: On or about 02/14/2018, and at times prior, the employer failed to inspect all of the electrical cords prior to the start of the work shift. Two 50-ft. extension cords were used to power circular saws and other equipment. Both cords used had missing ground pins which had not been removed from service or repaired.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342949666.