WASHINGTON, DC —
OSHA Inspection: BONILLA CARPENTRY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BONILLA CARPENTRY LLC in 1512 FOXHALL ROAD NW, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 342950912.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BONILLA CARPENTRY LLC
- Site address
- 1512 FOXHALL ROAD NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 11219 PEARTREE WAY, COLUMBIA, MD 21044
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Apr 11, 2018
- Penalty
- Initial $2,217 · Current $2,217
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about February 14, 2018; second floor area; employees were not wearing head protection while working under or near employees that were conducting demolition work of the roof or installing the rafters. No abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $2217
1926.404 B01 II
- Issued
- Apr 11, 2018
- Abate by
- Apr 19, 2018
- Penalty
- Initial $1,663 · Current $1,663
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection a) On or about February 14, 2018; throughout the site; employees were operating portable equipment such as but not limited to Makita 5007F circular saws that were not protected by a ground-fault circuit interrupter exposing them to a shock hazard. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1663
1926.501 B13
- Issued
- Apr 11, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about February 14, 2018; roof area of new addition; employees were not wearing fall protection while installing the rafters and conducting demolition of the residential roof exposing them a 10-30 foot fall b) On or about February 14, 2018; first floor; employees were working near a floor opening that was not guarded exposing them to a 10-foot fall to the lower level. No abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $3880
1926.1052 C01 II
- Issued
- Apr 11, 2018
- Penalty
- Initial $2,217 · Current $2,217
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge a) On or about February 14, 2018; access to second floor; the stairs used to access the upper floor did not have a stair-rail installed exposing employees to an 8-foot fall hazard to the lower level. No abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $2217
1926.503 B01
- Issued
- Apr 11, 2018
- Abate by
- Apr 19, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about February 14, 2018; throughout site; the employer had not ensured through certification that fall protection training was provided to the employees. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (O) $0
More inspections at Bonilla Carpentry LLC
View Bonilla Carpentry LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342950912.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.