Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: STEWART EFI, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STEWART EFI, LLC in 45 OLD WATERBURY ROAD, THOMASTON, CT 06787 (NAICS 336370). OSHA activity number 342951944.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stewart EFI, LLC for free Get an email when a new federal OSHA severe-injury report for Stewart EFI, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
STEWART EFI, LLC
Site address
45 OLD WATERBURY ROAD
City
THOMASTON
State
CT
ZIP
06787
Mailing
45 OLD WATERBURY ROAD, THOMASTON, CT 06787
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336370
Employees
107
Ownership type
Private (A)

2 citations on file for this inspection.

1910.217 D09 II

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2018
Penalty
Initial $4,989 · Current $3,492 Reduced
29 CFR 1910.217(d)(9)(ii): Spring loaded turnover bars were not provided for mechanical power press(es) designed to accept such turnover bars:   A.  On or about February 15, 2018, Press Department:  The turnover bar for the Minster #24, P3224 press did not have a spring to prevent it from becoming stuck in the flywheel.
Recent events (2)
  • · I (S) $3492.3
  • · Z (S) $4989

1910.303 B02

Serious Gravity 1 6 instances 10 exposed
Issued
Mar 16, 2018
Abate by
May 2, 2018
Penalty
Initial $4,157 · Current $2,910 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   A.  On or about February 15, 2018, Large Eyelet Department:  In the following instances, wall-mount listed 4-receptacle outlet boxes with perforated knockouts were used to provide pendant power, against listing instructions:  1. At the Asahi Seiki 506L eyelet machine, to provide power to a PA Industries pallet reel. 2. At the #B20 eyelet machine, to provide power to the Multi-Drive DC motor/speed control for the pallet reel. 3. At the #B18 eyelet machine, to provide power to the PA Industries pallet reel. 4. At the Asahi Seiki 505L eyelet machine, to provide power to a PA Industries pallet reel. 5. At the #WF2012-2 eyelet machine, to provide power to pallet reel equipment with no identifiable manufacturer name. 6. At the #WF2012-1 eyelet machine, to provide power to pallet reel equipment with no identifiable manufacturer name.
Recent events (2)
  • · I (S) $2909.9
  • · Z (S) $4157

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342951944.