THOMASTON, CT ·
OSHA Inspection: STEWART EFI, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STEWART EFI, LLC in 45 OLD WATERBURY ROAD, THOMASTON, CT 06787 (NAICS 336370). OSHA activity number 342951944.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEWART EFI, LLC
- Site address
- 45 OLD WATERBURY ROAD
- City
- THOMASTON
- State
- CT
- ZIP
- 06787
- Mailing
- 45 OLD WATERBURY ROAD, THOMASTON, CT 06787
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 107
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.217 D09 II
- Issued
- Mar 16, 2018
- Penalty
- Initial $4,989 · Current $3,492 Reduced
General-duty citation text
29 CFR 1910.217(d)(9)(ii): Spring loaded turnover bars were not provided for mechanical power press(es) designed to accept such turnover bars: A. On or about February 15, 2018, Press Department: The turnover bar for the Minster #24, P3224 press did not have a spring to prevent it from becoming stuck in the flywheel.
Recent events (2)
- · I (S) $3492.3
- · Z (S) $4989
1910.303 B02
- Issued
- Mar 16, 2018
- Abate by
- May 2, 2018
- Penalty
- Initial $4,157 · Current $2,910 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A. On or about February 15, 2018, Large Eyelet Department: In the following instances, wall-mount listed 4-receptacle outlet boxes with perforated knockouts were used to provide pendant power, against listing instructions: 1. At the Asahi Seiki 506L eyelet machine, to provide power to a PA Industries pallet reel. 2. At the #B20 eyelet machine, to provide power to the Multi-Drive DC motor/speed control for the pallet reel. 3. At the #B18 eyelet machine, to provide power to the PA Industries pallet reel. 4. At the Asahi Seiki 505L eyelet machine, to provide power to a PA Industries pallet reel. 5. At the #WF2012-2 eyelet machine, to provide power to pallet reel equipment with no identifiable manufacturer name. 6. At the #WF2012-1 eyelet machine, to provide power to pallet reel equipment with no identifiable manufacturer name.
Recent events (2)
- · I (S) $2909.9
- · Z (S) $4157
More inspections in this industry (NAICS 336370)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342951944.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.