Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAPITAL RECYCLING INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CAPITAL RECYCLING INC. in 3800 MOBILE HWY, MONTGOMERY, AL 36108 (NAICS 423510). OSHA activity number 342959756.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capital Recycling INC. — free Get an email when a new federal OSHA severe-injury report for Capital Recycling INC. is published. One employer, no account, unsubscribe in one click.
Site address
3800 MOBILE HWY
City
MONTGOMERY
State
AL
ZIP
36108
Mailing
P. O. BOX 9283, MONTGOMERY, AL 36108
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
9
Ownership type
A

9 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2018
Abate by
Mar 28, 2018
Penalty
Initial $2,356 · Current $2,356

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:   a)  Nex Gen Baler Machine operator and loader:   On or about February 21, 2018 and at times prior too,  the employer exposed an employee to noise dose at levels of 69.5 % (equivalent to an 8 hour time weighted average TWA of 87.3 dBA) which is 1.39 times the action level of 50% (equivalent to an 8 hour TWA of 85 dBA) while working operating baler, forklift and bobcat. Results were calculated for a 4780 minute sampling period with a zero concentration assumption for the remaining 2 minutes.  The employer did not administer a continuing, effective hearing conservation program.
Recent events (1)
  • — Z (S) $2356

1910.151 C

Other-than-serious 1 instance 3 exposed
Issued
Mar 16, 2018
Abate by
Mar 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   a)    Main shop recycling area:  On or about February 22, 2018 and at times prior, the employer exposed employees to loss of vision, skin burns and rashes, in that an emergency eyewash station was not located in the work area for immediate emergency use while employees while performing  daily job task of handling car batteries that contain acid.
Recent events (1)
  • — Z (O) $0

1910.134 C02 I

Other-than-serious 1 instance 3 exposed
Issued
Mar 16, 2018
Abate by
Mar 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:   a)     Main shop and outside areas:  On or about February 20, 2018 and at times prior to, the employer exposed employees to inhalation hazards from dust during work tasks while providing employees dust masks for voluntary use and did not provide employees with training on Appendix D of the respiratory protection standard.
Recent events (1)
  • — Z (O) $0

1910.134 D01 II

Other-than-serious 1 instance 3 exposed
Issued
Mar 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification:   a)     Capital Recycling, Inc.:  On or about February 20, 2018 and prior to, employees were exposed to dust inhalation hazards from work tasks.  The employer provides and allows voluntary use of non NIOSH approved filtering face piece respirators (dust masks).
Recent events (1)
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 2 exposed
Issued
Mar 16, 2018
Abate by
Mar 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:   a)     Capital Recycling, Inc.:  On or about February 21, 2018 and at times prior to, the employer exposed employee(s) to safety hazards associated with powered industrial trucks and did not ensure the certification of employee/operator.
Recent events (1)
  • — Z (O) $0

1910.253 E03 II C 3

Other-than-serious 1 instance 2 exposed
Issued
Mar 16, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 2150X100

29 CFR 1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system:  a)    Yard area:  On or about February 21, 2018 and at times prior to, the employer exposed employees to safety hazards in that a flashback protector was not in place on the oxygen gas and propane gas used in the 4 foot scorpion cutting torch operation to cut up scrap metal.
Recent events (1)
  • — Z (O) $0

1910.253 B02 II

Other-than-serious 1 instance 1 exposed
Issued
Mar 16, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 2150

29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:   a)     Yard area:  On or about February 20, 2018, and at times prior to, the employer exposed employees to fire, burns and struck by hazards by not securing compressed gas propane tanks.
Recent events (1)
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 2 instances 1 exposed
Issued
Mar 16, 2018
Abate by
Mar 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   a)    Baler Machine Emergency Stop button south side of machine: On or about February 21, 2018 and at times prior, the employer exposed employees to electrical burns, and shock hazards, in that the wiring for the emergency stop button was exposed.     b)    Baler Machine Emergency Stop button north side of machine: On or about February 21, 2018 and at times prior, the employer exposed employees to electrical burns, and shock hazards, in that the wiring for the emergency stop button was exposed.
Recent events (1)
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Mar 16, 2018
Abate by
Mar 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   b)  Baler Operators Station Area:  On or about February 21, 2018 and at times prior to, the employer exposed employees to electrical hazards by allowing temporary wiring to be used as permanent wiring to provide power to a 4 foot diameter fan.
Recent events (1)
  • — Z (O) $0

View Capital Recycling INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342959756.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.