Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RELINTLESS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RELINTLESS, LLC in 721 LAFAYETTE HIGHWAY, ROANOKE, AL 36274 (NAICS 423220). OSHA activity number 342961562.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Relintless, LLC — free Get an email when a new federal OSHA severe-injury report for Relintless, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
RELINTLESS, LLC
Site address
721 LAFAYETTE HIGHWAY
City
ROANOKE
State
AL
ZIP
36274
Mailing
721 LAFAYETTE HIGHWAY, ROANOKE, AL 36274
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423220
Employees
126
Ownership type
A

3 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 2 exposed
Issued
May 25, 2018
Abate by
Jun 21, 2018
Penalty
Initial $4,240 · Current $2,544 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition:    (a) On or about 02/20/2018 - Old Gymnasium, employees were exposed to struck-by hazards due to the entrance passageway missing cinder blocks and the wooden frame being damaged.
Recent events (2)
  • — I (S) $2544
  • — Z (S) $4240

1910.305 B01 II

Serious Gravity 1 1 instance 2 exposed
Issued
May 25, 2018
Penalty
Initial $4,240 · Current $2,544 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) On or about 02/20/2018 - Old Gymnasium, employees were exposed to electrical hazards due to unused openings in the electrical circuit panel box.
Recent events (2)
  • — I (S) $2544
  • — Z (S) $4240

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
May 25, 2018
Penalty
Initial $4,240 · Current $2,544 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a) On or about 02/20/2018 - Old Gymnasium, strain relief was not provided for the flexible cord used to power the DeWALT impact wrench.
Recent events (2)
  • — I (S) $2544
  • — Z (S) $4240

View Relintless, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342961562.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.