SCHAUMBURG, IL —
OSHA Inspection: TRI SECT CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TRI SECT CORPORATION in 717 MORSE AVE., SCHAUMBURG, IL 60193 (NAICS 325612). OSHA activity number 342962479.
Where did this inspection happen?
- Establishment
- TRI SECT CORPORATION
- Site address
- 717 MORSE AVE.
- City
- SCHAUMBURG
- State
- IL
- ZIP
- 60193
- Mailing
- 717 MORSE AVE., SCHAUMBURG, IL 60193
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325612
- Employees
- 8
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.146 C02
- Issued
- Jun 7, 2018
- Penalty
- Initial $2,217 · Current $1,340 Reduced
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: (a) Facility Wide - On February 21, 2018, the employer did not post danger signs or any other equally effective means, to warn employees of the existence of a permit confined spaces on tanks such as but not limited to the 600 gallon mixing tank. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1340
- — Z (S) $2217
1910.146 D03 III
- Issued
- Jun 7, 2018
- Abate by
- Jun 19, 2018
- Penalty
- Initial $2,772 · Current $1,630 Reduced
General-duty citation text
29 CFR 1910.146(d)(3)(iii): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations (a) Facility Wide - On February 21, 2018, the employer did not implement the procedures and practices necessary for the safe permit space entry when entering the 600 gallon mixing tank to clean the blades. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1630
- — Z (S) $2772
1910.146 D09
- Issued
- Jun 7, 2018
- Abate by
- Jun 19, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(9): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces (a) Facility Wide - On February 21, 2018, the employer did not implement the procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces when entering the 600 gallon mixing tank to clean the blades. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 E01
- Issued
- Jun 7, 2018
- Abate by
- Jun 19, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit: (a) Facility Wide - On February 21, 2018, the employer did not document the completion of measures necessary for safe entry by completing an entry permit prior to entering the 600 gallon mixing tank to clean the blades. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Jun 7, 2018
- Penalty
- Initial $2,772 · Current $1,630 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Facility Wide - On or about April 21, 2018, the employer did not ensure that a lockout device was affixed on the circuit breaker for the 600 gallon mixing tanks prior to employees performing servicing and maintenance tasks such as cleaning the blades. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1630
- — Z (S) $2772
1910.147 C04 II B
- Issued
- Jun 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a) Facility Wide - On or about February 21, 2018, the employer did not ensure that the energy control procedures clearly outlined the steps for shutting down and securing water valves on the 600 gallon tank when performing cleaning in the tank. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Jun 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: (a) Facility Wide - On or about February 21, 2018, the employer did not ensure that forklift refresher training was provided to employees once every three years. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at TRI Sect Corporation
View TRI Sect Corporation's full OSHA safety record →
More inspections in this industry (NAICS 325612)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342962479.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.