MOOSIC, PA —
OSHA Inspection: KENTREL CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of KENTREL CORPORATION in 820 SPRINGBROOK AVENUE, MOOSIC, PA 18507 (NAICS 237110). OSHA activity number 342965761.
Where did this inspection happen?
- Establishment
- KENTREL CORPORATION
- Site address
- 820 SPRINGBROOK AVENUE
- City
- MOOSIC
- State
- PA
- ZIP
- 18507
- Mailing
- 820 SPRINGBROOK AVENUE, MOOSIC, PA 18507
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 45
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.146 D04 I
- Issued
- Abate by
- Penalty
- Initial $5497.00 · Current $4500.00 Reduced
05608890X100
General-duty citation text
29 CFR 1910.146(d)(4)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not ensure that testing and monitoring equipment needed to comply with 29 CFR 1910.146(d)(5) was maintained properly: a) 301 Hanover Village, Wilkes-Barre, an employee entered a permit required confined space and the space had not been evaluated with a gas monitoring device that had been calibrated in accordance with the manufacturer's recommendations, on or about, March 15, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4500
- — Z (S) $5497
1926.1204 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
0560X100
General-duty citation text
29 CFR 1926.1204(d)(1): Under the permit-required confined space program required by 29 CFR 1926.1204, the employer did not ensure that testing and monitoring equipment needed to comply was maintained properly: a) 300 Broadway Street, Scranton, an employee entered a permit required confined space and the space had not been evaluated with a gas monitoring device that had been calibrated in accordance with the manufacture's recommendations, on or about, February 27, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1204 C07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
0640
General-duty citation text
29 CFR 1926.1204(c)(7): Under the permit-required confined space program the employer did not develop and implement the means, procedures, and practices necessary for safe permit entry operations, including, but not limited to, verifying that conditions in the permit space are acceptable for entry throughout the duration of an authorized entry: a) 300 Broadway Street, Scranton, an entrant inside a permit required confined space released pressurized chlorinated vapor, mist and water into the space during pipe venting, and the entry supervisor did not verify that conditions in the permit space were acceptable for entry during that time period, on or about, February 27, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.23 D07
- Issued
- Abate by
- Penalty
- Initial $4398.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.23(d)(7): Fixed ladders did not have grab bars that extend 42 inches (1.1 m) above the access level or landing platforms served by each ladder: a) 301 Hanover Village, Wilkes-Barre, an employee was exposed to a fall hazard of approximately 6 feet 8 inches while entering a permit required space, and a fixed ladder that was used was not equipped with a grab bar or side rail extension on each side that extended above the hatch frame, on or about, February 27, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $4398
1910.23 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $3000.00
General-duty citation text
29 CFR 1910.23(b)(2): Ladder rungs, steps, and cleats were not spaced not less than 10 inches (25 cm) and not more than 14 inches (36 cm) apart, as measured between the centerlines of the rungs, cleats, and steps: a) 301 Hanover Village, Wilkes-Barre, an employee was exposed to a fall hazard of approximately 6 feet 8 inches while entering a permit required space, and the distance between the hatch top and the first rung of the fixed ladder was approximately 25 inches, on or about, March 15, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3000
- — Z (S) $0
1926.1053 A24
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(a)(24): The side rails of through or sidestep fixed ladders did not extend 42 inches (1.1 m) above the top of the access level or landing platform served by the ladder: a) 300 Broadway Street, Scranton, an employee was exposed to a fall hazard of approximately 7 feet 6 inches while entering a permit required space, and a fixed ladder that was used was not equipped with a side rail on each side, that extended above the hatch frame, on or about, February 27, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 A03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(a)(3)(i): Rungs, cleats, and steps of fixed ladders were spaced more than 14 inches (36 cm) apart, as measured along the ladder's side rails: a) 300 Broadway Street, Scranton, an employee was exposed to a fall hazard of approximately 7 feet 6 inches while entering a permit required space, and the distance from the top of the hatch to the first rung of the fixed ladder was approximately 24 inches, on or about, February 27, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 K02 III
- Issued
- Abate by
- Penalty
- Initial $4398.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.146(k)(2)(iii): The employer did not ensure that each member of the rescue service was trained in basic first-aid and in cardiopulmonary resuscitation (CPR): a) 301 Hanover Village, Wilkes-Barre, an employee entered a permit required confined space and the attendant was not trained and currently certified to at least the Basic First Aid and CPR Levels in accordance with the American Red Cross or equivalent provider, on or about, March 15, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $1500
- — Z (S) $4398
1926.1211 B03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1211(b)(3): The employer did not ensure that each member of the rescue service was trained in basic first-aid and in cardiopulmonary resuscitation (CPR): a) 300 Broadway Street, Scranton, an employee entered a permit required confined space and the attendant was not trained and currently certified to at least the Basic First Aid and CPR Levels in accordance with the American Red Cross or equivalent provider, on or about, February 27, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.133 A01
- Issued
- Abate by
- Penalty
- Initial $3298.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) 301 Hanover Village, Wilkes-Barre, an employee hammered upon cold chisels, nail bar, and screw drivers with a carpentry claw hammer while spreading metal pipe spools and components and did not wear safety glasses, on or about, March 15, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $1000
- — Z (S) $3298
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) 300 Broadway Street, Scranton, an employee hammered upon cold chisels, nail bar, and screw drivers with a carpentry claw hammer while spreading metal pipe spools and components and did not wear safety glasses, on or about, February 27, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.146 E06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
05608890X100
General-duty citation text
29 CFR 1910.146(e)(6): The employer did not retain each canceled entry permit for at least one year to facilitate the review of the permit-required confined space program required by 29 CFR 1910.146(d)(14): a) Various sites, employees entered permit required spaces and copies of the permits were not maintained for at least the previous calendar year, observed on or about February 22, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.146 G04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
05608890X100
General-duty citation text
29 CFR 1910.146(g)(4): The employer did not certify that the training required by 29 CFR 1910.146(g)(1) through 29 CFR 1910.146(g)(3) had been accomplished: a) 301 Hanover Village, Wilkes-Barre, an employee entered a permit required confined space, and a written certification of the employee's training was not maintained, on or about, March 15, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1207 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
05608890X100
General-duty citation text
29 CFR 1926.1207(d): The employer did not certify that the training required by 29 CFR 1926.1207(a) through 29 CFR 1926.1207(c) had been accomplished: a) 300 Broadway Street, Scranton, an employee entered a permit required confined space, and a written certification of the employee's training was not maintained, on or about, February 27, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 237110)
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
CHICAGO, IL—2026-07-15
SUSTAINABLE SEWER & WATER INC.
LAKE FOREST, IL—2026-07-15
GREVERS CORPORATION DBA NORTH SHORE BORING
CHEYENNE, WY—2026-07-15
AZTEC CONSTRUCTION
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source