JANESVILLE, WI —
OSHA Inspection: CARROLL CONSTRUCTION LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CARROLL CONSTRUCTION LLC in 423/425 CENTER AVENUE, JANESVILLE, WI 53548 (NAICS 238160). OSHA activity number 342965993.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARROLL CONSTRUCTION LLC
- Site address
- 423/425 CENTER AVENUE
- City
- JANESVILLE
- State
- WI
- ZIP
- 53548
- Mailing
- 1141 MILDRED CIRCLE, EDGERTON, WI 53534
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B01
- Issued
- Apr 11, 2018
- Abate by
- May 2, 2018
- Penalty
- Initial $2,772 · Current $1,247 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part. On or about February 22, 2018, and times prior, the employer did not initiate and maintain safety and health programs.
Recent events (2)
- — I (S) $1247
- — Z (S) $2772
1926.21 B02
- Issued
- Apr 11, 2018
- Abate by
- May 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about February 22, 2018, and times prior, the employer did not instruct each individual on the recognition and avoidance of unsafe conditions and the regulations applicable to the work environment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Apr 11, 2018
- Abate by
- May 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about February 22, 2018, individuals exposed to fall hazards were not trained on how to recognize and mitigate those fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.100 A
- Issued
- Apr 11, 2018
- Abate by
- Apr 19, 2018
- Penalty
- Initial $2,217 · Current $1,247 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: On or about February 22, 2018, individuals performing site clean-up underneath additional individuals performing application of weatherproofing materials on a residential rooftop were doing so without head protection.
Recent events (2)
- — I (S) $1247
- — Z (S) $2217
1926.501 B13
- Issued
- Apr 11, 2018
- Abate by
- Apr 19, 2018
- Penalty
- Initial $3,880 · Current $2,910 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about February 22, 2018, individuals installing roof sheathing, ice/water, and felt paper on a residential rooftop at a height greater than six feet were doing so without fall protection.
Recent events (2)
- — I (S) $2910
- — Z (S) $3880
More inspections at Carroll Construction LLC
View Carroll Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342965993.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.