Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FENIX LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FENIX LLC in 820 SOUTH WILLIPIE STREET, WAPAKONETA, OH 45895 (NAICS 331222). OSHA activity number 342967130.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fenix LLC — free Get an email when a new federal OSHA severe-injury report for Fenix LLC is published. One employer, no account, unsubscribe in one click.
Establishment
FENIX LLC
Site address
820 SOUTH WILLIPIE STREET
City
WAPAKONETA
State
OH
ZIP
45895
Mailing
820 SOUTH WILLIPIE STREET, WAPAKONETA, OH 45895
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331222
Employees
41
Ownership type
A

4 citations on file for this inspection.

1910.137 C02 VIII

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 6, 2018
Abate by
May 5, 2018
Penalty
Initial $6,467 · Current $3,880 Reduced
29 CFR 1910.137(c)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests. Test voltages and/or the maximum intervals between tests were not conducted in accordance with Table I-4 and Table I-5.    a)      On February 22, 2018, the employer did not assure that electrical protective rubber gloves, used by electricians during electrical troubleshooting and testing, were tested at least once every six months.
Recent events (2)
  • — I (S) $3880.2
  • — Z (S) $6467

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 6, 2018
Abate by
May 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:   a)  On or about February 22, 2018, the employer did not ensure that employees who were performing troubleshooting on energized 480 volt circuit on motor starter on the shot blaster used personal protective equipment to protect against electrical hazards.  Employees were exposed to electrical shock and arc flash hazards in that electrical personal protective equipment was not worn while performing electrical work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 6, 2018
Abate by
May 4, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     a)  On or about February 22, 2018 the employer did not ensure the take up reels on line 2 were adequately guarded.  Employees are exposed to struck by hazards while the take up reels are operating.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1910.146 C07 III

Other-than-serious 1 instance 2 exposed
Issued
Apr 6, 2018
Abate by
May 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(7)(iii): The employer did not document the basis for determining that all hazards in a permit space had been eliminated, through a written certification that contained the date, the location of the space, and the signature of the person:   a) On or about February 22, 2018 the employer did not document and certify the reason in which the space associated with the cooling towers 1, 2, 3 and 4 were reclassified to a non-permit required confined space.  The multiple energies associated with units have to be locked out prior to entering.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Fenix LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342967130.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.