NEW ALBANY, MS —
OSHA Inspection: KEVIN CHARLES FURNITURE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KEVIN CHARLES FURNITURE in 927 SAM P. BARKLEY DRIVE, NEW ALBANY, MS 38652 (NAICS 337121). OSHA activity number 342968351.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEVIN CHARLES FURNITURE
- Site address
- 927 SAM P. BARKLEY DRIVE
- City
- NEW ALBANY
- State
- MS
- ZIP
- 38652
- Mailing
- 927 SAM P. BARKLEY DRIVE, NEW ALBANY, MS 38652
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337121
- Employees
- 68
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.219 I02
- Issued
- Mar 12, 2018
- Penalty
- Initial $9,054 · Current $5,432 Reduced
General-duty citation text
29 CFR 1910.219(i)(2): Bolt(s), nuts, or setscrews used in shaft coupling(s) extended beyond the flange of the coupling and were not covered with safety sleeve(s). (a) Fiber-Filling Machine - On or about February 20, 2018 exposed nuts and bolts on rotating shaft coupling were not guarded.
Recent events (2)
- — I (S) $5432.4
- — Z (S) $9054
1910.219 C02 I
- Issued
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting (a) Fiber-Filling Machine - On or about February 20, 2018 exposed rotating horizontal shaft was not guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 C04 I
- Issued
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end projected more than one half the diameter of the shaft. (a) Fiber-Filling Machine - On or about February 20, 2018 exposed rotating shafting projected more than one half the diameter of the shaft.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 H01
- Issued
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(h)(1): All projecting keys, setscrews, and other projections in revolving parts shall be removed or made flush or guarded by metal cover. This subparagraph does not apply to keys or setscrews within gear or sprocket casings or other enclosures, nor to keys, setscrews, or oilcups in hubs of pulleys less than twenty (20) inches in diameter where they are within the plane of the rim of the pulley. (a) Fiber-Filling Machine - On or about February 20, 2018 exposed rotating shaft with key projected above keyway.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Kevin Charles Furniture
View Kevin Charles Furniture's full OSHA safety record →
More inspections in this industry (NAICS 337121)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342968351.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.