Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAD PETROLEUM INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MAD PETROLEUM INC. in 1790 S BUCKLEY RD, AURORA, CO 80017 (NAICS 811111). OSHA activity number 342969367.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MAD Petroleum INC. — free Get an email when a new federal OSHA severe-injury report for MAD Petroleum INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MAD PETROLEUM INC.
Site address
1790 S BUCKLEY RD
City
AURORA
State
CO
ZIP
80017
Mailing
1790 S BUCKLEY RD, AURORA, CO 80017
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
11
Ownership type
A

4 citations on file for this inspection.

1910.1200 E01

Serious Gravity 1 1 instance 11 exposed
Issued
Jun 12, 2018
Abate by
Jun 29, 2018
Penalty
Initial $1,995 · Current $998 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a) On or about February 22, 2018, and at times prior, the employer did not ensure that a hazard communication program was available at 1790 S Buckley Rd in Aurora, CO 80017 for employees required to use hazardous chemicals such as but not limited to ZEP Commercial Purple Cleaner and Degreaser which is used to clean automotive parts and contains sodium hydroxide which may cause severe skin burns and eye damage.    Abatement Note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $997.5
  • — Z (S) $1995

1910.1200 F06 I

Serious Gravity 1 2 instances 11 exposed
Issued
Jun 12, 2018
Abate by
Jun 29, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):  (a) On or about February 22, 2018, and at times prior, the employer did not ensure that  secondary chemical containers such as plastic spray bottles that contained chemicals such as but not limited to ZEP Commercial Purple Cleaner and Degreaser, which is used to clean automotive parts and contains sodium hydroxide which may cause severe skin burns and eye damage, were properly labeled with a hazard warning.  Abatement Note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 2 instances 11 exposed
Issued
Jun 12, 2018
Abate by
Jun 22, 2018
Penalty
Initial $1,995 · Current $998 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    (a) On or about February 22, 2018, and at times prior, the employer did not ensure that outlets and light switches in the bay area had covers to protect employees from electrical shock or burns.    Abatement Note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $997.5
  • — Z (S) $1995

1910.303 G01

Other-than-serious 1 instance 11 exposed
Issued
Jun 12, 2018
Abate by
Jun 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a) On or about February 22, 2018, and at times prior, the employer did not ensure that employees were protected from electrical hazards by ensuring necessary access to electrical panels in the storage room of the shop. They were blocked from access by a wood panel.  Abatement Note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342969367.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.