Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENCO INDUSTRIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GENCO INDUSTRIES, INC. in 209 WILMONT DR., WAUKESHA, WI 53189 (NAICS 333249). OSHA activity number 342971462.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Genco Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Genco Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
209 WILMONT DR.
City
WAUKESHA
State
WI
ZIP
53189
Mailing
209 WILMONT DR., WAUKESHA, WI 53189
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333249
Employees
43
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 43 exposed
Issued
May 11, 2018
Abate by
Jun 30, 2018
Penalty
Initial $6,596 · Current $3,000 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) A written Energy Control Program (Lockout/Tagout) was not developed and implemented to ensure employee(s) who perform maintenance, repair, machine set-up and other associated mechanical diagnostic procedures on but not limited to Molex TM4000 Terminal Press, automated Cut & Strip Benchtop (10-30ga.), automated Cut & Strip cable processing equipment, automated Cut & Strip Large Gauge (to 4/0), bench top wire stripping equipment, automatic-apply labeling equipment, and other manufacturing equipment were not exposed to unexpected energizing, startup or release of stored energy from mechanical equipment.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $6596

1910.147 C04 I

Serious Gravity 10 1 instance 43 exposed
Issued
May 11, 2018
Abate by
Jun 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   (a) Written machine/equipment specific energy control procedures were not developed, documented, and utilized by authorized personnel to follow when performing maintenance, repair, set-up and other associated mechanical diagnostic procedures on, but not limited to Molex TM4000 Terminal Press, automated Cut & Strip Benchtop (10-30ga.), automated Cut & Strip cable processing equipment, automated Cut & Strip Large Gauge, bench top wire stripping equipment, automatic-apply labeling equipment, and other manufacturing equipment and processes.  This exposed employees to mechanical and pneumatic energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 10 1 instance 43 exposed
Issued
May 11, 2018
Abate by
Jun 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    (a) Authorized employees were not trained to properly isolate energy sources prior to performing maintenance or servicing of equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 1 instance 4 exposed
Issued
May 11, 2018
Abate by
Jun 7, 2018
Penalty
Initial $9,054 · Current $5,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed to prevent the operator from having any part of his/her body in the danger zone during the operating cycle.    (a) Molex MT4000 Terminal Press; Serial #1147; 3.5 ton capacity: The terminal press point of operation was not properly guarded, allowing the operator to inadvertently place fingers into the point of operation.  This exposed the operator to a crushing hazard and amputation injury.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9054

1910.132 D02

Other-than-serious 1 instance 42 exposed
Issued
May 11, 2018
Abate by
Jun 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.  (A) The employer did not certify that the required workplace hazard assessment was performed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Genco Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342971462.