WAUKESHA, WI —
OSHA Inspection: GENCO INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GENCO INDUSTRIES, INC. in 209 WILMONT DR., WAUKESHA, WI 53189 (NAICS 333249). OSHA activity number 342971462.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENCO INDUSTRIES, INC.
- Site address
- 209 WILMONT DR.
- City
- WAUKESHA
- State
- WI
- ZIP
- 53189
- Mailing
- 209 WILMONT DR., WAUKESHA, WI 53189
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333249
- Employees
- 43
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C01
- Issued
- May 11, 2018
- Abate by
- Jun 30, 2018
- Penalty
- Initial $6,596 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) A written Energy Control Program (Lockout/Tagout) was not developed and implemented to ensure employee(s) who perform maintenance, repair, machine set-up and other associated mechanical diagnostic procedures on but not limited to Molex TM4000 Terminal Press, automated Cut & Strip Benchtop (10-30ga.), automated Cut & Strip cable processing equipment, automated Cut & Strip Large Gauge (to 4/0), bench top wire stripping equipment, automatic-apply labeling equipment, and other manufacturing equipment were not exposed to unexpected energizing, startup or release of stored energy from mechanical equipment.
Recent events (2)
- — I (S) $3000
- — Z (S) $6596
1910.147 C04 I
- Issued
- May 11, 2018
- Abate by
- Jun 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Written machine/equipment specific energy control procedures were not developed, documented, and utilized by authorized personnel to follow when performing maintenance, repair, set-up and other associated mechanical diagnostic procedures on, but not limited to Molex TM4000 Terminal Press, automated Cut & Strip Benchtop (10-30ga.), automated Cut & Strip cable processing equipment, automated Cut & Strip Large Gauge, bench top wire stripping equipment, automatic-apply labeling equipment, and other manufacturing equipment and processes. This exposed employees to mechanical and pneumatic energy sources.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- May 11, 2018
- Abate by
- Jun 30, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. (a) Authorized employees were not trained to properly isolate energy sources prior to performing maintenance or servicing of equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- May 11, 2018
- Abate by
- Jun 7, 2018
- Penalty
- Initial $9,054 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed to prevent the operator from having any part of his/her body in the danger zone during the operating cycle. (a) Molex MT4000 Terminal Press; Serial #1147; 3.5 ton capacity: The terminal press point of operation was not properly guarded, allowing the operator to inadvertently place fingers into the point of operation. This exposed the operator to a crushing hazard and amputation injury.
Recent events (2)
- — I (S) $5000
- — Z (S) $9054
1910.132 D02
- Issued
- May 11, 2018
- Abate by
- Jun 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. (A) The employer did not certify that the required workplace hazard assessment was performed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Genco Industries, INC.
View Genco Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333249)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342971462.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.