GALETON, PA —
OSHA Inspection: PATTERSON LUMBER CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PATTERSON LUMBER CO., INC. in 95 WEST STREET, GALETON, PA 16922 (NAICS 321113). OSHA activity number 342971512.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PATTERSON LUMBER CO., INC.
- Site address
- 95 WEST STREET
- City
- GALETON
- State
- PA
- ZIP
- 16922
- Mailing
- 95 WEST STREET, GALETON, PA 16922
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 54
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.265 C04 IV
- Issued
- Apr 9, 2018
- Penalty
- Initial $3,298 · Current $2,309 Reduced
General-duty citation text
29 CFR 1910.265(c)(4)(iv): Elevated walk(s) and runway(s), 4 feet or more from floor level(s), were not provided with both a standard railing and a toe board. a) Debarker Walkway, 95 West Street, Galeton, PA - Employees utilized a walkway that was six (6) foot above the ground which lacked a standard railing on the left side entering the building exposing employees to a fall hazard, as observed on or about February 23, 2018. In accordance with 29 CFR 1903.19, abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
- — I (S) $2308.6
- — Z (S) $3298
1910.265 C05 II
- Issued
- Apr 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.265(c)(5)(ii): Stairways were not provided with a standard handrail on at least one side or on any open side. a) Green Mill Deck, 95 West Street, Galeton, PA - Employees exited and entered a forty-three (43) inch high wooden deck by using a flight of stairs (six risers, five treads) that lacked a standard handrail on the right side ascending exposing the employees to a fall hazard, as observed on or about February 23, 2018. In accordance with 29 CFR 1903.19, abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.335 A01 I
- Issued
- Apr 9, 2018
- Abate by
- Apr 27, 2018
- Penalty
- Initial $3,298 · Current $2,309 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. a) Facility, 95 West Street, Galeton, PA - Employees who performed troubleshooting and servicing tasks (voltage testing, fuse removal/replacement, etc.) on energized 110V to 480V electrical components were not provided an arc-rated suit hood (balaclava) and an arc-rated long-sleeved shirt and pants or arc-rated coveralls exposing the employees to the hazards associated with an arc flash/blast, on or about February 23, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this item.
Recent events (2)
- — I (S) $2308.6
- — Z (S) $3298
1910.335 A01 IV
- Issued
- Apr 9, 2018
- Abate by
- Apr 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(iv): Employees exposed to the danger of head injury from electric shock or burns due to contact with exposed energized parts did not wear nonconductive head protection. a) Facility, 95 West Street, Galeton, PA - Employees who performed troubleshooting and servicing tasks (voltage testing, fuse removal/replacement, etc.) on energized 110V to 480V electrical components were not provided nonconductive head protection exposing the employees to the hazards associated with an arc flash/blast, on or about February 23, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.265 C06 IV
- Issued
- Apr 9, 2018
- Abate by
- May 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.265(c)(6)(iv): Sliding doors. Where a sliding door was used as an exit, an inner door was not cut inside the main door and arranged to open outward. a) Planer Shed, 95 West Street, Galeton, PA - Employees entered or exited the Planer Shed through a sliding door that lacked an outward opening inner door exposing the employees to slip, trip, or fall hazards in the event of an emergency situation, as observed on or about February 23, 2018. In accordance with 29 CFR 1903.19, abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Patterson Lumber CO., INC.
View Patterson Lumber CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342971512.