Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PATTERSON LUMBER CO., INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PATTERSON LUMBER CO., INC. in 95 WEST STREET, GALETON, PA 16922 (NAICS 321113). OSHA activity number 342971512.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Patterson Lumber CO., INC. — free Get an email when a new federal OSHA severe-injury report for Patterson Lumber CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
95 WEST STREET
City
GALETON
State
PA
ZIP
16922
Mailing
95 WEST STREET, GALETON, PA 16922
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
54
Ownership type
A

5 citations on file for this inspection.

1910.265 C04 IV

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 9, 2018
Penalty
Initial $3,298 · Current $2,309 Reduced
29 CFR 1910.265(c)(4)(iv): Elevated walk(s) and runway(s), 4 feet or more from floor level(s), were not provided with both a standard railing and a toe board.  a) Debarker Walkway, 95 West Street, Galeton, PA - Employees utilized a walkway that was six (6) foot above the ground which lacked a standard railing on the left side entering the building exposing employees to a fall hazard, as observed on or about February 23, 2018.  In accordance with 29 CFR 1903.19, abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
  • — I (S) $2308.6
  • — Z (S) $3298

1910.265 C05 II

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.265(c)(5)(ii): Stairways were not provided with a standard handrail on at least one side or on any open side.  a) Green Mill Deck, 95 West Street, Galeton, PA - Employees exited and entered a forty-three (43) inch high wooden deck by using a flight of stairs (six risers, five treads) that lacked a standard handrail on the right side ascending exposing the employees to a fall hazard, as observed on or about February 23, 2018.  In accordance with 29 CFR 1903.19, abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 9, 2018
Abate by
Apr 27, 2018
Penalty
Initial $3,298 · Current $2,309 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed.        a) Facility, 95 West Street, Galeton, PA - Employees who performed troubleshooting and servicing tasks (voltage testing, fuse removal/replacement, etc.) on energized 110V to 480V electrical components were not provided an arc-rated suit hood (balaclava) and an arc-rated long-sleeved shirt and pants or arc-rated coveralls exposing the employees to the hazards associated with an arc flash/blast, on or about February 23, 2018.  In accordance with 29 CFR 1903.19, abatement certification is required for this item.
Recent events (2)
  • — I (S) $2308.6
  • — Z (S) $3298

1910.335 A01 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2018
Abate by
Apr 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(iv): Employees exposed to the danger of head injury from electric shock or burns due to contact with exposed energized parts did not wear nonconductive head protection.  a) Facility, 95 West Street, Galeton, PA - Employees who performed troubleshooting and servicing tasks (voltage testing, fuse removal/replacement, etc.) on energized 110V to 480V electrical components were not provided nonconductive head protection exposing the employees to the hazards associated with an arc flash/blast, on or about February 23, 2018.  In accordance with 29 CFR 1903.19, abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.265 C06 IV

Other-than-serious 1 instance 2 exposed
Issued
Apr 9, 2018
Abate by
May 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.265(c)(6)(iv): Sliding doors. Where a sliding door was used as an exit, an inner door was not cut inside the main door and arranged to open outward.  a) Planer Shed, 95 West Street, Galeton, PA - Employees entered or exited the Planer Shed through a sliding door that lacked an outward opening inner door exposing the employees to slip, trip, or fall hazards in the event of an emergency situation, as observed on or about February 23, 2018.  In accordance with 29 CFR 1903.19, abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Patterson Lumber CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342971512.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.