WOODRIDGE, IL —
OSHA Inspection: PARKER-HANNIFIN CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PARKER-HANNIFIN CORP. in 10625 BEAUDIN BLVD., WOODRIDGE, IL 60517 (NAICS 326291). OSHA activity number 342979291.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARKER-HANNIFIN CORP.
- Site address
- 10625 BEAUDIN BLVD.
- City
- WOODRIDGE
- State
- IL
- ZIP
- 60517
- Mailing
- 10625 BEAUDIN BLVD., WOODRIDGE, IL 60517
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326291
- Employees
- 220
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.137 C02 VIII
- Issued
- Aug 22, 2018
- Abate by
- Sep 13, 2018
- Penalty
- Initial $10,163 · Current $7,114 Reduced
General-duty citation text
29 CFR 1910.137(c)(2)(viii): Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5: On or about 24 February 2018, the employer did not ensure that the rubber insulating gloves issued for employee use had been electrically tested (or replaced) at 6 month intervals. The gloves had an inspection date of July 2012. Employees were exposed to electric shock hazards when performing electrical work. Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $7114.1
- — Z (S) $10163
1910.147 C04 II
- Issued
- Aug 22, 2018
- Abate by
- Sep 28, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: On or about 28 February 2018, the documented procedures in the employer's lockout/tagout program did not adequately outline techniques to be utilized to verify control and determine the effectiveness of stored energy pressure release (air, hydraulic, fuel gas) on machines including the Hydraulic Rubber Molding Press, Sleeve Cutter/Timmer, and Gas Ovens. Employees who gained access to equipment during servicing and maintenance were exposed to caught-in hazards. Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Parker-Hannifin Corp.
View Parker-Hannifin Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 326291)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342979291.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.