Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AFFORDABLE ROOFING & GUTTERS OF FLORIDA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AFFORDABLE ROOFING & GUTTERS OF FLORIDA, INC. in 605 SW 49TH LANE 609 SW 49TH LANE, CAPE CORAL, FL 33904 (NAICS 238160). OSHA activity number 342979531.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Affordable Roofing & Gutters of Florida, INC. — free Get an email when a new federal OSHA severe-injury report for Affordable Roofing & Gutters of Florida, INC. is published. One employer, no account, unsubscribe in one click.
Site address
605 SW 49TH LANE 609 SW 49TH LANE
City
CAPE CORAL
State
FL
ZIP
33904
Mailing
921 SE 15TH AVE, CAPE CORAL, FL 33990
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
11
Ownership type
A

6 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 2 instances 11 exposed
Issued
May 23, 2018
Abate by
Jun 19, 2018
Penalty
Initial $9,054 · Current $9,054
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a) For employees working at 605 SW 49th Lane in Cape Coral on or about February 27, 2018.  Employees were installing new roofing shingles on the 6:12 pitch roof without the use of any type of fall protection system in place. The employees were exposed to a fall height greater than 8 feet.   b) For employees working at 609 SW 49th Lane in Cape Coral on or about February 27, 2018.  Employees were installing new roofing shingles on the 6:12 pitch roof without the use of any type of fall protection system in place. The employees were exposed to a fall height greater than 8 feet.
Recent events (1)
  • — Z (S) $9054

1926.503 B01

Serious Gravity 10 2 instances 11 exposed
Issued
May 23, 2018
Abate by
Jun 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a) For employees working at 605 SW 49th Lane in Cape Coral on or about February 27, 2018.  Employees were installing new roofing shingles on the 6:12 pitch roof without the use of any type of fall protection system in place. The employees were exposed to a fall height greater than 8 feet. Employer does not have a certified record of training for employees.  b) For employees working at 609 SW 49th Lane in Cape Coral on or about February 27, 2018.  Employees were installing new roofing shingles on the 6:12 pitch roof without the use of any type of fall protection system in place. The employees were exposed to a fall height greater than 8 feet. Employer does not have a certified record of training for employees.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
May 23, 2018
Penalty
Initial $6,467 · Current $6,467
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    a) For employees working at 605 SW 49th Lane in Cape Coral on or about February 27, 2018.  Employees were using a step ladder that was not tall enough to reach the upper landing level. The employee stepped off the top of the ladder onto the roof surface. The employee was exposed to a fall height greater than 8 feet.
Recent events (1)
  • — Z (S) $6467

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
May 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:   a) For employees working at 605 SW 49th Lane in Cape Coral on or about February 27, 2018.  Employees were using a step ladder to reach the upper landing level. The employee stepped off the top of the ladder onto the roof surface. The employee was exposed to a fall height greater than 8 feet.
Recent events (1)
  • — Z (S) $0

1926.1060 A

Serious Gravity 5 1 instance 1 exposed
Issued
May 23, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways:  a) For employees working at 605 SW 49th Lane in Cape Coral on or about February 27, 2018.  Employees were using a step ladder that was not tall enough to reach the upper landing level. The employee stepped off the top of the ladder onto the roof surface. The employee was exposed to a fall height greater than 8 feet. The employer failed to provide training in the proper hazards associated with the use of a stepladder.
Recent events (1)
  • — Z (S) $0

1926.405 G02 IV

Other-than-serious 1 instance 6 exposed
Issued
May 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  b) For employees working at 609 SW 49th Lane in Cape Coral on or about February 27, 2018.  Employees were using a portable power tools on the roof that were powered by an extension cord that was not provided with strain relief at the plug end. The outer insulation was pulled back approximately 1 1/2 inch exposing the inner insulated conductors. The employees were exposed to a electrical shock.