OSHA Inspection: UPSTATE PRINTING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UPSTATE PRINTING INC. in 433 W. ONONDAGA STREET, SYRACUSE, NY 13202 (NAICS 323111). OSHA activity number 342979630.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Upstate Printing INC. — free Get an email when a new federal OSHA severe-injury report for Upstate Printing INC. is published. One employer, no account, unsubscribe in one click.
Site address
433 W. ONONDAGA STREET
City
SYRACUSE
State
NY
ZIP
13202
Mailing
433 WEST ONONDAGA STREET, SYRACUSE, NY 13202
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
17
Ownership type
A

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 1 10 instances 10 exposed
Issued
Mar 26, 2018
Abate by
Apr 30, 2018
Penalty
Initial $2,218 · Current $1,664 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a)  At the establishment, on or about 2/28/18:  The employer did not ensure that operators of a Crown SX 3000 walkie stacker lift were formally trained and evaluated.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1663.5
  • — Z (S) $2218

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 26, 2018
Abate by
Apr 30, 2018
Penalty
Initial $3,696 · Current $2,772 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)  Digital Room, on or about 2/28/18:  Point of operation on a Acme Champion stitcher was not guarded.  b)  Press Room, on or about 2/28/18:  Ingoing nip points at the ink rollers on a Ryobi printing press, Model 3985, were not guarded.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $2772
  • — Z (S) $3696

1910.147 C04 I

Other-than-serious 1 instance 10 exposed
Issued
Mar 26, 2018
Abate by
Apr 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a)  At the establishment, on or about 2/28/18:   Where employees perform servicing, maintenance, set up, changeovers, etc. on various machinery or equipment, including, but not limited to printing presses, cutters, folders, compressors, etc., the employer had not established specific energy control procedures (lockout/tagout) to prevent the unexpected energizing, start up or release of stored energy of the equipment.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 G05

Other-than-serious 2 instances 1 exposed
Issued
Mar 26, 2018
Abate by
Apr 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a)  Press Room, on or about 2/28/18:  A Polar Aire fan and a trouble light were not grounded in that the ground pins were missing from their plug ends.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Mar 26, 2018
Abate by
Apr 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  Mail Room, on or about 2/28/18:  Extension cord providing current to a strapper at the inkjet mailing equipment was being used as permanent wiring.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Upstate Printing INC.'s full OSHA safety record →