WASHINGTON, DC —
OSHA Inspection: D & H DEMOLITION, LLC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of D & H DEMOLITION, LLC. in 1510 NORTH CAPITOL STREET, NW, WASHINGTON, DC 20001 (NAICS 238990). OSHA activity number 342985751.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D & H DEMOLITION, LLC.
- Site address
- 1510 NORTH CAPITOL STREET, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20001
- Mailing
- 889 AIRPORT PARK ROAD, SUITE C, GLEN BURNIE, MD 21061
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.850 A
- Issued
- Apr 20, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations: a) Job Site - An engineering survey to determine the structural integrity of the row house was not performed prior to the start of demolition, on or about 10/28/2017. No abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $3880
1926.854 B
- Issued
- Apr 20, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.854(b): Wall sections more than one story in height were permitted to stand alone without lateral bracing when the wall section was not originally designed to stand alone without such lateral support: a) Front Northeast Corner - Bracing was not provided on a 16 inch wide section of brick façade that was three stories in height and collapsed as a result and injured workers at the site, on or about 10/28/2017. No abatement certification or documentation required for this item.