OSHA Inspection: SPOONER MACHINE INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SPOONER MACHINE INC in 1100 ROUNDHOUSE ROAD, SPOONER, WI 54801 (NAICS 332710). OSHA activity number 342986890.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spooner Machine INC — free Get an email when a new federal OSHA severe-injury report for Spooner Machine INC is published. One employer, no account, unsubscribe in one click.
Establishment
SPOONER MACHINE INC
Site address
1100 ROUNDHOUSE ROAD
City
SPOONER
State
WI
ZIP
54801
Mailing
1100 ROUNDHOUSE ROAD, SPOONER, WI 54801
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
40
Ownership type
A

19 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 26, 2019
Abate by
Jan 3, 2020
Penalty
Initial $9,282 · Current $5,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) The water table at plasma arc cutter; The employer did not develop, document and utilize procedures for the control of hydrogen gas when employees were engaged in cleaning, maintenance and repair of the water table.
Recent events (2)
  • — Z (S) $9282
  • — I (S) $5000

1910.101 B

Serious Gravity 1 2 instances 30 exposed
Issued
Aug 22, 2018
Abate by
Sep 6, 2018
Penalty
Initial $3,880 · Current $10,000
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    (a) Compressed gas cylinder  storage area; The employer did not ensure that cylinder storage areas were prominently posted with the names of the gases to be stored in accordance with the ACG P-1 1965, 3.3.2.    (b) Compressed gas cylinder  storage area; Where gases of different types are stored at the same location the employer did not ensure cylinders were grouped by types of gas, and the groups arranged to take into account the gases contained, in accordance with ACG P-1 1965, 3.3.3.
Recent events (3)
  • — F (S) $10000
  • — C (S) $3880
  • — Z (S) $3880

1910.253 B04 III

Serious Gravity 1 1 instance 30 exposed
Issued
Aug 22, 2018
Abate by
Sep 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least:  (a) Compressed gas cylinder storage area; The employer had stored reserve stocks of cylinders containing liquid petroleum gas with cylinders containing oxygen.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 1 instance 20 exposed
Issued
Aug 22, 2018
Abate by
Oct 12, 2018
Penalty
Initial $9,054 · Current $5,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:    (a) The production area; The employer did not perform periodic inspections of the energy control procedures on equipment such as but not limited to Bridgeport Mills, Laser Cutter, Automatic Saw, Profile Saw, Okuma Computer Numerical Control (CNC) machine, Shear, Hole Wizard, Strippet, Hurco VM2,  Hurco TM8 and other machines and equipment at the facility.
Recent events (3)
  • — F (S) $5000
  • — C (S) $9054
  • — Z (S) $9054

1910.147 C07 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 22, 2018
Abate by
Oct 12, 2018
Penalty
Initial $9,054 · Current $5,000 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    (a) The production area; The employer did not provide training for employees as authorized employees to perform lock out of hazardous energy sources prior to performing cleaning, maintenance or repairs of equipment such as but not limited to the water table used for plasma arc cutting and the Accurpress 400 ton press.
Recent events (3)
  • — F (S) $5000
  • — C (S) $9054
  • — Z (S) $9054

1910.147 C08

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 22, 2018
Abate by
Oct 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(8): Lockout or tagout was not performed only by the authorized employees who are performing the servicing or maintenance:  (a) The production area; The supervisor affixed energy isolating devices to hazardous energy sources, on behalf of the employees, when the employees performed cleaning, maintenance, or repairs of equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 22, 2018
Abate by
Sep 6, 2018
Penalty
Initial $9,054 · Current $5,000 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    (a) The Accurpress 400 ton press; The employer did not ensure that lock out devices were affixed to the Accurpress 400 ton press while repairs were being performed.
Recent events (3)
  • — F (S) $5000
  • — C (S) $9054
  • — Z (S) $9054

1910.178 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 22, 2018
Penalty
Initial $3,880 · Current $5,000
29 CFR 1910.178(f)(2): The storage and handling of liquefied petroleum gas fuel was not in accordance with NFPA Storage and Handling of Liquefied Petroleum Gases (NFPA No. 58-1969), which is incorporated by reference as specified in Sec. 1910.6:    (a) Yale powered industrial vehicle; A removable fuel container of liquid petroleum (LP) was not securely mounted to prevent jarring loose, slipping or rotating.
Recent events (3)
  • — F (S) $5000
  • — C (S) $3880
  • — Z (S) $3880

1910.180 D04 X

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 22, 2018
Abate by
Oct 12, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1910.180(d)(4)(x): Periodic inspection of mobile cranes were not performed for excessively worn or damaged tires:  (a) The Broderson carry deck crane; The employer did not ensure that a periodic inspection of tires was performed.
Recent events (3)
  • — F (S) $0
  • — C (S) $9054
  • — Z (S) $9054

1910.243 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 22, 2018
Abate by
Sep 6, 2018
Penalty
Initial $6,467 · Current $5,000 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):    (a) In the production area; The employer did not ensure portable grinders were guarded.
Recent events (3)
  • — F (S) $5000
  • — C (S) $6467
  • — Z (S) $6467

1910.305 B01 II

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 22, 2018
Abate by
Sep 20, 2018
Penalty
Initial $0 · Current $5,000
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) In the production area; The employer was utilizing electrical boxes that were designed for in-wall (concealed) or on-wall (exposed) installations for electrical drop installations throughout the production area. 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) In the production area; The employer was utilizing electrical drop service installations which had boxes with unused opening that were not effectively closed.
Recent events (3)
  • — F (S) $5000
  • — C (S) $9054
  • — Z (S) $9054

1910.305 G02 III

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 22, 2018
Abate by
Sep 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) In the welding area; The flexible cord that supplies power to the Lincoln Electric power MIG metal inert gas welder was not installed to prevent tension from being transmitted to joints or terminal screws.    (b) Safan Darley brake press; The flexible cord that supplies power to the foot pedal that actuates the Safan brake press was not installed to prevent tension from being transmitted to joints or terminal screws
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1200 E01 I

Serious Gravity 5 1 instance 30 exposed
Issued
Aug 22, 2018
Abate by
Sep 20, 2018
Penalty
Initial $6,467 · Current $5,000 Reduced
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet:    (a) The production area; The employer did not maintain a complete and accurate list of all chemicals including but not limited to oxygen, acetylene, liquid petroleum gas, plasma arc torch coolant, metals, and metal alloys present at the facility.
Recent events (3)
  • — F (S) $5000
  • — C (S) $6467
  • — Z (S) $6467

1910.1200 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 22, 2018
Abate by
Oct 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  (a) The production area; The employer did not maintain a safety data sheet in the workplace for chemical hazards including but not limited to ESAB plasma arc torch coolant, metals, and metal alloys present at the facility.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1200 J02 II

Serious Gravity 5 1 instance 30 exposed
Issued
Aug 22, 2018
Abate by
Oct 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(j)(2)(ii): Employees were not provided effective information and training on hazardous chemicals in their work area in accordance with the update to the hazard communication program required by paragraph (h)(1) and (h)(3):    (a) Throughout the facility; Training was not provided to inform employees of the Global Harmonization System changes for container labeling and safety data sheet (SDS) format.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 22, 2018
Abate by
Oct 12, 2018
Penalty
Initial $0 · Current $5,000
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    (a) Water table at plasma arc cutter; The employer did not ensure that all energy isolating devices needed to control the buildup of hazardous gasses were physically located and operated in such a manner as to isolate the hazardous energy source, such as but not limited to, Hydrogen gas from the aluminum cutting process, when employees were engaged in cleaning, maintenance and repair of the water table.
Recent events (3)
  • — F (S) $5000
  • — C (W) $0
  • — Z (W) $0

1910.147 C04 I

Willful Gravity 10 1 instance 3 exposed
Issued
Aug 22, 2018
Abate by
Oct 12, 2018
Penalty
Initial $77,602 · Current $17,500 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) The Accurpress 400 ton press; The employer did not develop, document and utilize procedures for the control of hazardous energy sources such as but not limited to gravity, hydraulic, and electrical energy when employees were engaged in cleaning, maintenance and repair of the Accurpress 400 ton press.
Recent events (3)
  • — F (W) $17500
  • — C (W) $77602
  • — Z (W) $77602

1910.212 A03 II

Willful Gravity 10 1 instance 4 exposed
Issued
Aug 22, 2018
Abate by
Sep 20, 2018
Penalty
Initial $77,602 · Current $17,500 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) The Accurpress 400 ton press; On or about February 28, 2018 through March 5, 2018, the employer did not ensure the point of operation on the Accurpress 400T hydraulic press was guarded to prevent the employees from having any part of their bodies in the danger zone during the operating cycle.
Recent events (3)
  • — F (W) $17500
  • — C (W) $77602
  • — Z (W) $77602

1910.180 D06

Other-than-serious 1 instance 10 exposed
Issued
Aug 22, 2018
Abate by
Oct 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.180(d)(6): Monthly, dated and signed inspection records and reports for truck crane(s) were not provided for critical items such as (but not limited to) brakes, crane hooks and ropes:  (a) The Broderson carry deck crane; The employer did not ensure that monthly inspections were conducted for critical items such as but not limited to brakes, crane hooks, and wire ropes on the Broderson crane at the facility.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Spooner Machine INC's full OSHA safety record →