Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ANDRITZ INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ANDRITZ INC. in 220 SCARLET BLVD., OLDSMAR, FL 34677 (NAICS 332216). OSHA activity number 342993474.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Andritz INC. — free Get an email when a new federal OSHA severe-injury report for Andritz INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ANDRITZ INC.
Site address
220 SCARLET BLVD.
City
OLDSMAR
State
FL
ZIP
34677
Mailing
220 SCARLET BLVD., OLDSMAR, FL 34677
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332216
Employees
54
Ownership type
A

6 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 26, 2018
Abate by
Jul 23, 2018
Penalty
Initial $7,391 · Current $4,435 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least  (a) outside storage area - two oxygen cylinders, one empty and one filled, were stored with filled acetylene cylinders also in storage; observed on or about 2/28/2018.
Recent events (2)
  • — I (S) $4434.6
  • — Z (S) $7391

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 26, 2018
Abate by
Jul 23, 2018
Penalty
Initial $5,543 · Current $3,326 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) Grinding Room - the power cord of the sanding belt grinder (green frame) did not have a strain relief, exposing employees to an electric shock hazard; observed on or about 2/28/2018.
Recent events (2)
  • — I (S) $3325.8
  • — Z (S) $5543

1910.334 A02 II

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 26, 2018
Abate by
Jul 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): Where there was a defect or evidence of damage that could have exposed an employee to injury, the defective or damaged item was not removed from service, and was used by employees before repairs and tests necessary to render the equipment safe were made:  (a) Grinding Room - the power cord of the sanding belt grinder (green frame) was pulled and frayed at the connection, exposing employees to an electric shock hazard; observed on or about 2/28/2018.  (b) Grinding Room - the power cord of the sanding belt grinder (green frame) was damaged at areas along the length of the cord; observed on or about 2/28/2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 2 instances 54 exposed
Issued
Jun 26, 2018
Abate by
Jul 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) In the plant - the locations of at least two fire extinguishers were not identified; observed on or about 2/28/2018.  (b) In the office - the location of a fire extinguisher was not identified; observed on or about 2/28/2018.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 I

Other-than-serious 2 instances 2 exposed
Issued
Jun 26, 2018
Abate by
Jul 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  (a) At the workplace - cords were not inspected for damage; on or about 2/28/2018.  (b) Grinding Room - the entire length of the power cord of the shop light located to the right of the door could not be inspected for damage due to the orange tape wrapped around a portion of the cord; observed on or about 2/28/2018.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 23 exposed
Issued
Jun 26, 2018
Abate by
Jul 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) at the workplace - employees were not provided with training on the hazards associated with the chemicals used including, but not limited to, Neulube 4-Way lubricant and Simple Green Industrial Cleaner & Degreaser; on or about 2/28/2018.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0