SAINT LOUIS, MO —
OSHA Inspection: B & J PEERLESS RESTAURANT SUPPLY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of B & J PEERLESS RESTAURANT SUPPLY in 1616 DIELMAN ROAD, SAINT LOUIS, MO 63132 (NAICS 423440). OSHA activity number 342995404.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- B & J PEERLESS RESTAURANT SUPPLY
- Site address
- 1616 DIELMAN ROAD
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63132
- Mailing
- 1616 DIELMAN ROAD, SAINT LOUIS, MO 63132
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423440
- Employees
- 15
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A02
- Issued
- May 31, 2018
- Abate by
- Jun 26, 2018
- Penalty
- Initial $3,696 · Current $1,848 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition. On or about February 23, 2018, at the jobsite located 1616 Dielman Road, Saint Louis, Missouri the employer did not ensure the floor of each workroom was maintained in a dry condition in the following instances: 1. In the east corner of the showroom, the floor was wet resulting from a leaking roof that had not been repaired after several months of damage. This left employee(s) exposed to a slip and fall hazard. 2. Standing water near the north wall of the warehouse from the leaking roof exposed employee(s) to a slip and fall hazard. 3. Standing water in the forklift battery changing area near the south wall of the warehouse potentially exposing employee(s) to both electrical and slip and fall hazard.
Recent events (2)
- — I (O) $1848
- — Z (S) $3696
1910.132 A
- Issued
- May 31, 2018
- Abate by
- Jun 26, 2018
- Penalty
- Initial $3,696 · Current $1,848 Reduced
General-duty citation text
29 CFR 1910.132(a): Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. On or about February 23, 2018, at the jobsite located 1616 Dielman Road, Saint Louis, Missouri the employer did not employer did not provide personal protective equipment for employee(s) required to maintain powered industrial trucks in the following instances: 1. Employee(s) required to charge batteries in the battery charging area are not provided a face shield and apron to prevent contact with corrosive chemicals per manufacturer specifications. 2. Employee(s) required to change liquid propane cylinders are not provided gloves or eye protection to prevent contact with pressurized liquid propane.
Recent events (2)
- — I (O) $1848
- — Z (S) $3696
1910.133 A01
- Issued
- May 31, 2018
- Abate by
- Jun 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about February 23, 2018, at the jobsite located 1616 Dielman Road, Saint Louis, Missouri, the employer did not ensure each affected employee used the appropriate eye or face protection for the following tasks: 1. Employee(s) required to charge batteries in the battery charging area are not provided a face shield to prevent exposure to corrosive chemicals per manufacturer specifications. 2. Employee(s) required to change liquid propane cylinders were not provided eye protection to prevent contact with pressurized liquid propane.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 L01 II
- Issued
- May 31, 2018
- Penalty
- Initial $5,174 · Current $2,587 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck: On or about February 23, 2018, at the jobsite located 1616 Dielman Road, Saint Louis, Missouri, the employer did not ensure each employee had successfully completed training prior to operating powered industrial trucks. Employee(s) working in the warehouse operated powered industrial trucks without successfully completing the required training.
Recent events (2)
- — I (O) $2587
- — Z (S) $5174
1910.178 P01
- Issued
- May 31, 2018
- Abate by
- Jun 26, 2018
- Penalty
- Initial $5,174 · Current $2,587 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): If at any time a powered industrial truck was found to be in need of repair, defective, or in any way unsafe, the truck was not taken out of service until it was restored to safe operating condition. On or about February 23, 2018, at the jobsite located 1616 Dielman Road, Saint Louis, Missouri, the employer did not ensure powered industrial trucks in need of repair, defective, or in any way unsafe was taken out of service in the following instances: 1. The Yale Veracitor 40VX Forklift (Model No. GLC0405VXNUSE 082; Serial No. C809V09791E) was in operation with disconnected front lights, broken (inoperable) rear lights 2. The Nissan Forklift (Model No. MCPL01A15LV; Chassis No. CPL01 9N1313) broken rear lights with shrink wrap used to keep them in place.
Recent events (2)
- — I (O) $2587
- — Z (S) $5174
1910.178 Q07
- Issued
- May 31, 2018
- Abate by
- Jun 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were examined before being placed in service, and were placed in service when the examination showed any condition adversely affecting the safety of the vehicle. Defects when found were not immediately reported and corrected. On or about February 23, 2018, at the jobsite located 1616 Dielman Road, Saint Louis, Missouri, the employer did not ensure that when defects were found with Yale Veracitor 40VX Forklift (Model No. GLC0405VXNUSE 082; Serial No. C809V09791E); and Nissan Forklift (Model No. MCPL01A15LV; Chassis No. CPL01 9N1313) that they were either removed from service. Warehouse employee(s) were observed operating the forklifts with disconnected headlights and broken, inoperable rear lights.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections in this industry (NAICS 423440)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342995404.