Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HOLLISTER CONSTRUCTION SERVICES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HOLLISTER CONSTRUCTION SERVICES, LLC in 210 MAIN ST, HACKENSACK, NJ 07601 (NAICS 236220). OSHA activity number 342999208.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hollister Construction Services, LLC — free Get an email when a new federal OSHA severe-injury report for Hollister Construction Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
210 MAIN ST
City
HACKENSACK
State
NJ
ZIP
07601
Mailing
339 JEFFERSON ROAD, PARSIPPANY, NJ 07054
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
140
Ownership type
A

7 citations on file for this inspection.

1926.153 G

Other-than-serious 1 instance 3 exposed
Issued
Jun 22, 2018
Penalty
Initial $9,977 · Current $0 Reduced
29 CFR 1926.153(g): Liquefied petroleum gas (LP-Gas) containers installed outside of buildings or structures were not upright upon firm foundation or otherwise firmly secured:    a) Exterior of Building - Left Side: Employees were exposed to thermal burns and struck by hazards as approximately 50 - 100 lbs LP-Gas containers were located over uneven ground covered with sheets of plywood. Some of the containers were connected by hoses onto heaters inside the building. The containers were not level and were not secured in any way, on or about 2/9/18
Recent events (3)
  • — C (S) $9977
  • — F (O) $0
  • — Z (S) $9977

1926.153 K01

Other-than-serious 3 instances 3 exposed
Issued
Jun 22, 2018
Penalty
Initial $6,652 · Current $5,322 Reduced
29 CFR 1926.153(k)(1): Storage outside of buildings, for containers awaiting use, shall be located from the nearest building or group of buildings, in accordance with the following:                       TABLE F-3      _______________________________________        Quantity of LP-Gas stored    Distance                                      (feet)      _____________________________ _________      500 lbs. or less............         0      501 to 6,000 lbs............        10      6,001 to 10,000 lbs.........        20      Over 10,000 lbs.............        25      _____________________________ _________        a) Exterior of Building - Left Side: Approximately twenty  - 100 lbs LP-Gas  and 4 - 200 lbs LP-Gas  containers were located in a parking area less than 10 feet from the building, on or about 2/9/18      b) Exterior of Building - Front - Under Scaffolds: Eight - 200 lbs LP-Gas  containers were located under the frame scaffold approximately 2 feet from the building, on or about 2/12/18      c) Exterior of Building - Moore St Sidewalk - Next to Dumpster: Four - 200 lbs LP-Gas containers were located next to 30 yard debris container approximately 1 foot from the building, on or about 2/12/18
Recent events (3)
  • — C (S) $6652
  • — F (O) $5321.6
  • — Z (S) $6652

1926.153 O

Other-than-serious 2 instances 3 exposed
Issued
Jun 22, 2018
Penalty
Initial $9,977 · Current $7,982 Reduced
29 CFR 1926.153(o): When damage to LP-Gas systems from vehicular traffic was a possibility, precautions against such damage were not taken:      a) Exterior of Building - Left Side: Approximately 50 - 100 lbs LP-Gas  and 4 - 200 lbs LP-Gas  containers were located in a parking area without any barrier to protect them against vehicular traffic, on or about 2/9/18      b) Exterior of Building - Moore St Sidewalk - Next to Dumpster: 4 - 200 lbs LP-Gas containers were located next to 30 yard debris container, on or about 2/12/18
Recent events (3)
  • — C (S) $9977
  • — F (O) $7981.6
  • — Z (S) $9977

1926.552 C02

Other-than-serious 1 instance 3 exposed
Issued
Jun 22, 2018
Penalty
Initial $8,315 · Current $0 Reduced
29 CFR 1926.552(c)(2): 29 CFR 1926.552(c)(2):  Towers inside of structures shall be enclosed on all four sides throughout the full height.        a) Interior of Building - HEK Personnel Hoist: Employees were exposed to struck by hazards while utilizing a personnel hoist without all four sides being enclosed, on or about 2/9/18
Recent events (3)
  • — C (S) $8315
  • — F (O) $0
  • — Z (S) $8315

1926.552 C05

Serious Gravity 5 3 instances 3 exposed
Issued
Jun 22, 2018
Penalty
Initial $8,315 · Current $6,652 Reduced
29 CFR 1926.552(c)(5): Cars shall be permanently enclosed on all sides and the top, except sides used for entrance and exit which have car gates or doors.          a) Interior of Building - HEK Personnel Hoist: Employees were exposed to fall, amputation and struck by hazards while utilizing a personnel hoist without enclosed sides and top, on or about 2/9/18    b) Interior of Building - HEK Personnel Hoist: Employees were exposed to fall, amputation and struck by hazards while utilizing a personnel hoist without enclosed sides and top, on or about 2/12/18    c) Interior of Building - HEK Personnel Hoist: Employees were exposed to fall, amputation and struck by hazards while utilizing a personnel hoist without enclosed sides and top, on or about 3/16/18
Recent events (3)
  • — C (S) $8315
  • — F (S) $6652
  • — Z (S) $8315

1926.552 C07

Other-than-serious 3 instances 3 exposed
Issued
Jun 22, 2018
Penalty
Initial $8,315 · Current $6,652 Reduced
29 CFR 1926.552(c)(7): Overhead protective covering of 2-inch planking, 3/4-inch plywood or other solid material or equivalent strength shall be provided on the top of every personnel hoist.      a) Interior of Building - HEK Personnel Hoist: Employees were exposed to struck by hazards while utilizing a personnel hoist without overhead solid and strong protective covering, on or about 2/9/18    b) Interior of Building - HEK Personnel Hoist: Employees were exposed to struck by hazards while utilizing a personnel hoist without overhead solid and strong protective covering, on or about 2/12/18    c) Interior of Building - HEK Personnel Hoist: Employees were exposed to struck by hazards while utilizing a personnel hoist without overhead solid and strong protective covering, on or about 3/16/18
Recent events (3)
  • — C (S) $8315
  • — F (O) $6652
  • — Z (S) $8315

1926.552 C08

Other-than-serious 3 instances 3 exposed
Issued
Jun 22, 2018
Penalty
Initial $8,315 · Current $6,652 Reduced
29 CFR 1926.552(c)(8): Personnel hoist doors or gates were not provided with electrical contacts which do not allow movement of the hoist when door or gate was open:      a) Interior of Building - HEK Personnel Hoist: Employees were exposed to amputation and fall hazards while utilizing a personnel hoist without any doors or gates, on or about 2/9/18    b) Interior of Building - HEK Personnel Hoist: Employees were exposed to amputation and fall hazards while utilizing a personnel hoist with a gate without an electrical contact, on or about 2/12/18    c) Interior of Building - HEK Personnel Hoist: Employees were exposed to amputation and fall hazards while utilizing a personnel hoist with a gate without an electrical contact, on or about 3/16/18
Recent events (3)
  • — C (S) $8315
  • — F (O) $6652
  • — Z (S) $8315

View Hollister Construction Services, LLC's full OSHA safety record →