BEATRICE, NE —
OSHA Inspection: CUSTOM FIXTURES INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CUSTOM FIXTURES INC in 201 S 2ND ST, BEATRICE, NE 68310 (NAICS 337127). OSHA activity number 343006508.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM FIXTURES INC
- Site address
- 201 S 2ND ST
- City
- BEATRICE
- State
- NE
- ZIP
- 68310
- Mailing
- 201 S 2ND ST, BEATRICE, NE 68310
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337127
- Employees
- 48
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 25, 2018
- Abate by
- Jul 20, 2018
- Penalty
- Initial $9,054 · Current $5,430 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: The employer is failing to protect employees from caught in, amputation, and struck by hazards while operating a drill press. This was most recently observed at 201 S 2nd St, Beatrice, Nebraska on March 9, 2018 when the following drill presses were observed being used without guarding around the rotating chuck. a. Rockwell Drill Press b. Clausing Multi Head Drill Press
Recent events (2)
- — I (S) $5430
- — Z (S) $9054
1910.213 C02
- Issued
- Jun 25, 2018
- Abate by
- Jul 20, 2018
- Penalty
- Initial $3,880 · Current $2,340 Reduced
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: The employer is failing to protect employees from struck by hazards when operating table saws. This was most recently observed at 201 S 2nd St, Beatrice, Nebraska on March 9, 2018 when employees were performing rip cuts on a table saw that did not have a spreader to prevent kick backs.
Recent events (2)
- — I (S) $2340
- — Z (S) $3880
1910.213 C03
- Issued
- Jun 25, 2018
- Abate by
- Jul 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: The employer is failing to protect employees from struck by hazards when operating a table saw. This was most recently observed at 201 S 2nd St, Beatrice, Nebraska on March 9, 2018 when employees were performing rip cuts and table saws that did not have non kickback fingers installed to prevent kickbacks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H01
- Issued
- Jun 25, 2018
- Abate by
- Jul 20, 2018
- Penalty
- Initial $9,054 · Current $5,430 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the stock being cut to give maximum protection possible for the operation being performed: The employer is failing to protect employees from amputation hazards when operating a radial arm saw. This was most recently observed at 201 S 2nd St, Beatrice, Nebraska on March 9, 2018 when employees were operating a radial arm saw that did not have a guarding device installed to protect from contact with the spinning blade.
Recent events (2)
- — I (S) $5430
- — Z (S) $9054
1910.303 B02
- Issued
- Jun 25, 2018
- Abate by
- Aug 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: The employer is failing to protect employees from electrical hazards from drop cords in the workplace. This was most recently observed at 201 S 2nd St, Beatrice, Nebraska on March 9, 2018 when an electrical junction box with knock outs was being used in conjunction with a drop cord from the ceiling and was not permanently mounted to a structure..
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Jun 25, 2018
- Abate by
- Aug 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: Two power cord drops did not have strain relief and the outer insulation was pulled away from the inner wires. (no exposed copper)
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Custom Fixtures INC
View Custom Fixtures INC's full OSHA safety record →
More inspections in this industry (NAICS 337127)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343006508.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.