MIAMI, FL —
OSHA Inspection: CLIFFHANGER JANITORIAL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CLIFFHANGER JANITORIAL, INC. in 3900 NW 25TH ST. RENTAL CAR CENTER, MIAMI, FL 33142 (NAICS 561720). OSHA activity number 343009940.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLIFFHANGER JANITORIAL, INC.
- Site address
- 3900 NW 25TH ST. RENTAL CAR CENTER
- City
- MIAMI
- State
- FL
- ZIP
- 33142
- Mailing
- 5541 NW 74TH AVENUE, MIAMI, FL 33166
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.27 B02 IV
- Issued
- Jul 24, 2018
- Abate by
- Aug 17, 2018
- Penalty
- Initial $6,467 · Current $6,467
General-duty citation text
29 CFR 1910.27(b)(2)(iv): The rope descent system is inspected at the start of each work-shift that it is to be used. The employer must ensure damaged or defective equipment is removed from service immediately and replaced; On or about February 22nd 2018, at the worksite located at 3900 NW 25th St, Rental Car Center access ramp, Miami FL. 33142, the employee did not inspect the worksite at the start of each work-shift, to verify that there was an unrated, defective clamp with no visual serial number in the site and was not removed immediately.
Recent events (1)
- — Z (S) $6467
1910.27 B02 VII
- Issued
- Jul 24, 2018
- Abate by
- Aug 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.27(b)(2)(vii): (vii) All components of each rope descent system, except seat boards, are capable of sustaining a minimum rated load of 5,000 pounds (22.2 kN). Seat boards must be capable of supporting a live load of 300 pounds (136 kg); On or about February 22nd 2018, at the worksite located at 3900 NW 25th St, rental Car Center access ramp, Miami FL 33142, the employer did not ensure the unrated clamp uses as part of the rope descent system was able to sustain a minimum rated load of 5,000 pounds (22.2 kN).
Recent events (1)
- — Z (S) $0
1910.30 C
- Issued
- Jul 24, 2018
- Penalty
- Initial $6,467 · Current $6,467
General-duty citation text
29 CFR 1910.30(c): (c) Retraining. The employer must retrain an employee when the employer has reason to believe the employee does not have the understanding and skill required by paragraphs (a) and (b) of this section. Situations requiring retraining include, but are not limited to, the following: On or about February 22nd 2018, at the worksite located at 3900 NW 25th St, rental Car Center access ramp, Miami FL 33142, the employer did not retrained an employee while the employee wrongly: a. Had an unrated and defective clamp in the company truck. b. Selected the wrong clamp for the type of structure to be attached. c. Using a bosun chair with frayed straps.
Recent events (1)
- — Z (S) $6467
1910.66 G03 I
- Issued
- Jul 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.66(g)(3)(i): A maintenance inspection and, where necessary, a test shall be made of each platform installation every 30 days, or where the work cycle is less than 30 days such inspection and/or test shall be made prior to each work cycle. This inspection and test shall follow procedures recommended by the manufacturer, and shall be made by a competent person. On or about February 22nd 2018, at the worksite located at 3900 NW 25th St, rental Car Center entrance ramp, Miami FL 33142, the employer did not perform an inspection of a boatswain chair which had frayed straps and signs of damage.
Recent events (1)
- — Z (O) $0
More inspections at Cliffhanger Janitorial, INC.
View Cliffhanger Janitorial, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 561720)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343009940.