LEOMINSTER, MA —
OSHA Inspection: QUAD/GRAPHICS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of QUAD/GRAPHICS, INC. in 27 NASHUA ST, LEOMINSTER, MA 01453 (NAICS 323111). OSHA activity number 343018610.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUAD/GRAPHICS, INC.
- Site address
- 27 NASHUA ST
- City
- LEOMINSTER
- State
- MA
- ZIP
- 01453
- Mailing
- 27 NASHUA ST, LEOMINSTER, MA 01453
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 122
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C04 II A
- Issued
- Jul 12, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $12,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(A): The Energy Control Procedures did not include a specific statement of the intended use of the procedure. Site: In the production area, at the facility at 27 Nashua Street, Leominster, MA 01453, on 6/5/2018 Energy Control Procedures did not include a specific statement of the intended use of the procedure for the following:. (a) Hazardous Energy Control Procedure Form HS-019 for the Bobst SA; (b) Hazardous Energy Control Procedure Form SH-060 for the XL-105; (c) Hazardous Energy Control Procedure Form M1000 for the M1000 Press Rear Splicer (a.k.a. Butler); (d) Hazardous Energy Control Procedure Form FC-087 for the 414 Flat Cutter; (e) Hazardous Energy Control Procedure Form SH-060 for the CD Press; (f) Hazardous Energy Control Procedure Form FM-174 for the MBO Folder; (g) Hazardous Energy Control Procedure Form "Trimmer" for the Corona Binder Trimmer; (h) Hazardous Energy Control Procedure Form "Steinemann" for the Steinemann Laminator.
Recent events (3)
- — F (S) $0
- — C (S) $12934
- — Z (S) $12934
1910.147 C04 II B
- Issued
- Jul 12, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not include specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: Site: In the production plant at 27 Nashua Street, Leominster, MA 01453, on 6/5/18 energy control procedures did not did not include specific procedural steps for shutting down, isolating, blocking and securing 90 psi pneumatic energy to the: (a) Bobst (b) M1000 Press Rear Splicer (c) 414 flat cutter (d) CD Press (e) MBO folder.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C04 II D
- Issued
- Jul 12, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control. Site: In the production area, at the facility at 27 Nashua Street, Leominster, MA 01453, on 6/5/2018 Energy Control Procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control for the following: (a) Hazardous Energy Control Procedure Form HS-019 for the Bobst SA; (b) Hazardous Energy Control Procedure Form SH-060 for the XL-105; (c) Hazardous Energy Control Procedure Form M1000 for the M1000 Press Rear Splicer (a.k.a. Butler); (d) Hazardous Energy Control Procedure Form FC-087 for the 414 Flat Cutter; (e) Hazardous Energy Control Procedure Form SH-060 for the CD Press; (f) Hazardous Energy Control Procedure Form FM-174 for the MBO Folder; (g) Hazardous Energy Control Procedure Form "Trimmer" for the Corona Binder Trimmer; (h) Hazardous Energy Control Procedure Form "Steinemann" for the Steinemann Laminator.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C06 I C
- Issued
- Jul 12, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $12,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. (a) Site: In the production plant at 27 Nashua Street, Leominster, MA 01453, on 4/27/18 the periodic inspection for the Steinmann Laminator did not include a review, between the inspector and each authorized employee who performed the procedure being inspected. (b) Site: In the production plant at 27 Nashua Street, Leominster, MA 01453, on 4/27/18 the periodic inspection for the 414 Flat Cutter did not include a review, between the inspector and each authorized employee who performed the procedure being inspected.
Recent events (3)
- — F (S) $0
- — C (S) $12934
- — Z (S) $12934
1910.147 C07 I A
- Issued
- Jul 12, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $9,239 · Current $4,616 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. (a) Site: In the production plant at 27 Nashua Street, Leominster, MA 01453, on 6/5/2018 employees did not receive retraining to ensure they understood the intended use of the energy control procedures, the steps to shut down and isolate the pneumatic energy control procedures, the verification steps in the energy control procedures, and the type and magnitude of the energy control procedures when they were authorized to perform energy control procedure for the following equipment: (a) Bobst SA, (b) XL-105 (c) M1000 Press Rear Splicer (a.k.a. Butler) (d) 414 Flat Cutter (e) CD Press (f) MBO Folder (g) Corona Binder Trimmer (h) Steinemann Laminator
Recent events (3)
- — F (O) $4615.5
- — C (S) $9239
- — Z (S) $9239
1910.212 A03 II
- Issued
- Jul 12, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $7,391 · Current $3,696 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: Site: In the maintenance shop, at the facility, 27 Nashua Street, Leominster, MA 01453 on 5/9/2018 the following equipment did not contain guards that enclosed all portions of the bit and chuck above the material being worked on : (a) Sharp-LC Turret Milling machine, (b) WT Heavy Duty Drill Press, (c) Delta Table Mounted Drill Press
Recent events (3)
- — F (O) $3695.5
- — C (S) $7391
- — Z (S) $7391
1910.215 A04
- Issued
- Jul 12, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $7,391 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) Site: In the maintenance shop, at the facility at 27 Nashua Street, Leominster, MA 01453, on 5/9/2018 the work rest on the Baldor pedestal grinder was not adjusted closely to the wheel with a maximum opening of one eighth inch.
Recent events (3)
- — F (S) $0
- — C (S) $7391
- — Z (S) $7391
More inspections at Quad/Graphics, INC.
View Quad/Graphics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343018610.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.