OSHA Inspection: D.J. ELECTRIC, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of D.J. ELECTRIC, INC. in 9195 FOREST VIEW RD., KEWASKUM, WI 53040 (NAICS 238210). OSHA activity number 343022158.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D.J. Electric, INC. — free Get an email when a new federal OSHA severe-injury report for D.J. Electric, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
D.J. ELECTRIC, INC.
Site address
9195 FOREST VIEW RD.
City
KEWASKUM
State
WI
ZIP
53040
Mailing
3391 HWY. NN, WEST BEND, WI 53095
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

7 citations on file for this inspection.

1926.451 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 5, 2018
Penalty
Initial $3,326 · Current $3,326
29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it:  (a) A scaffold and its components were not capable of supporting 4 times the maximum intended load that was applied or transmitted to them. This resulted in a scaffold collapse.
Recent events (2)
  • — I (S) $3326
  • — Z (S) $3326

1926.451 A06

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person:  (a) A scaffold/scaffold platform that an employee was working from to install electrical components was not designed and erected by a qualified person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 5, 2018
Abate by
Aug 21, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  (a) An employee installing electrical equipment from a supported scaffold had not been trained on the hazards associated with scaffold work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F15

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 5, 2018
Penalty
Initial $3,326 · Current $0 Reduced
29 CFR 1926.451(f)(15): Ladders were used on scaffolds to increase the working level height of employees:     (a) A 2 foot portable step-ladder was used on a scaffold platform to gain extra height by an electrician installing electrical equipment. This exposed the employee to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3326

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 5, 2018
Abate by
Jul 11, 2018
Penalty
Initial $3,326 · Current $2,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a) An employee conducting electrical box installation from a second floor loft/deck area was not protected from falling to the lower level. This exposed the employee to a fall hazard of approximately nine (9) feet.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3326

1926.503 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 5, 2018
Abate by
Aug 21, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  (a)  The employer did not ensure that an employee exposed to a fall hazard from a second floor level had been trained to recognize and minimize the fall hazard associated with the work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1052 C01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 5, 2018
Abate by
Jul 11, 2018
Penalty
Initial $1,663 · Current $674 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    (a)  Employees were traversing and working from a stairway with four or more risers without at least one handrail in place.
Recent events (2)
  • — I (S) $674
  • — Z (S) $1663