AMHERST, NY —
OSHA Inspection: GOLDEN CONSTRUCTION NY CORP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GOLDEN CONSTRUCTION NY CORP in 4224 MAPLE ROAD, AMHERST, NY 14226 (NAICS 236220). OSHA activity number 343022992.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GOLDEN CONSTRUCTION NY CORP
- Site address
- 4224 MAPLE ROAD
- City
- AMHERST
- State
- NY
- ZIP
- 14226
- Mailing
- 131-48 40TH ROAD, #1A, FLUSHING, NY 11354
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- May 23, 2018
- Penalty
- Initial $1,885 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: a) On or about 03/07/18, at the eating area of the site, Amherst, NY. Employee who used a Bosch chop saw cutting 1-inch copper, did not wear safety goggles. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $1885
1926.403 I02 I
- Issued
- May 23, 2018
- Penalty
- Initial $1,885 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) On or about 03/07/18, at the kitchen area of the site, Amherst, NY. The energized panel of 120/208 Volt lacked the dead front and cover plate to prevent accidental contact. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $1885
1926.404 B01 II
- Issued
- May 23, 2018
- Penalty
- Initial $1,885 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) On or about 3/7/18, at the eating area of the site, Amherst, NY. The Bosch chop saw, that drew power through a flexible cord plugged into wall receptacles, lacked the ground fault circuit interrupters for personal protection. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $1885
1926.403 I02 III
- Issued
- May 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(2)(iii): Entrances to rooms and other guarded locations containing exposed live parts operating at 600 volts, nominal, or less were not marked with conspicuous warning signs forbidding unqualified persons to enter: a) On or about 03/07/18, at the kitchen area of the site, Amherst, NY. The entrance to the kitchen area, where the energized panel was located, was not marked with conspicuous warning signs. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343022992.