ORWIGSBURG, PA —
OSHA Inspection: MAE-EITEL, INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MAE-EITEL, INC in 97 PINEDALE INDUSTRIAL ROAD, ORWIGSBURG, PA 17961 (NAICS 332999). OSHA activity number 343023081.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAE-EITEL, INC
- Site address
- 97 PINEDALE INDUSTRIAL ROAD
- City
- ORWIGSBURG
- State
- PA
- ZIP
- 17961
- Mailing
- 97 PINEDALE INDUSTRIAL ROAD, ORWIGSBURG, PA 17961
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 42
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.107 B05 I
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $3,879 · Current $2,334 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained: a.) The Binks paint spray booth was not equipped with a manometer or other device to ensure that the required air speed was maintained, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2334
- — Z (S) $3879
1910.107 B10
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(10): Transparent panels used for illumination of spray booth(s) did not effectively isolate the spraying area from the area in which the lighting unit(s) were located: a.) The Binks paint spray booth had a cracked transparent panel on an overhead light, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B05 IV
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a.) The Binks paint spray booth was not equipped with approved automatic sprinklers on the downstream side of the filters where Acrolon 218 HS Polyurethane was sprayed, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B09
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a.) Combustibles such as cardboard, plywood, and lacquer thinner were stored directly adjacent to the outside walls of the Binks spray booth, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $3,879 · Current $2,333 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employees or whenever respirators are required by the employer, the employer did not establish and implement a written respiratory protection program with required worksite-specific procedures: a) The employer did not ensure that a written respiratory protection program was established and implemented for the painter who was required to wear a 3M half-mask respirators, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED ABATEMENT NOTE: The respiratory protection program shall include, at a minimum, procedures for selecting respirators; medical evaluations; fit testing; procedures for proper use in routine and reasonably foreseeable emergency situations; procedures for cleaning, storing, inspecting, repairing and discarding respirators; employee training regarding respiratory hazards they are exposed to, proper uses and limitations of respirators; and procedures for regularly evaluating the effectiveness of the respirator program.
Recent events (2)
- — I (S) $2333
- — Z (S) $3879
1910.134 F02
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) The painter was required to use a 3M half-mask respirator, and a fit test was not provided, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) The painter was required to use a 3M half-mask respirator, and a medical evaluation was not provided, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H01 I
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition: (a) The 3M half mask respirator was not maintained in a sanitary condition, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $3,879 · Current $2,333 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) The painter was exposed to flammable paints and solvents and the employer did not develop, implement, and/or maintain at the workplace a written hazard communication program, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2333
- — Z (S) $3879
1910.1200 F06 II
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: (a) A secondary container of lacquer thinner was not labeled with a hazard warning of the chemical contained therein, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Apr 27, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment (a) The painter was exposed to paints and solvents and the employer did not provide the employee with effective information and training on hazardous chemicals, on or about 3-16-18. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 332999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343023081.