OMAHA, NE —
OSHA Inspection: TYSON FOODS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of TYSON FOODS, INC. in 13027 RENFRO CIRCLE, OMAHA, NE 68137 (NAICS 311612). OSHA activity number 343027140.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TYSON FOODS, INC.
- Site address
- 13027 RENFRO CIRCLE
- City
- OMAHA
- State
- NE
- ZIP
- 68137
- Mailing
- 13027 RENFRO CIRCLE, OMAHA, NE 68137
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 300
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.119 J02
- Issued
- Sep 18, 2018
- Penalty
- Initial $8,638 · Current $8,638
0170
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not implement written procedures to maintain the on-going integrity of process equipment for correcting deficiencies such as the labeling of process valves and gauges. The employer is failing to correct the deficiency of improper identification of ammonia process components in the following instances: A) A pressure gauge PI #130252 for Liquid Pump #32 of the +30 Processing Recirculator in Engine Room #1 was mislabeled as PI #13252. B) A "dead-man" type valve #130238 from the oil pot of the +30 Processing Recirculator in Engine Room #1 was missing its identification tag/label. C) A valve #130237 on a line from the oil pot of the +30 Processing Recirculator in Engine Room #1 was mislabeled as #130236. These deficiencies were last observed on June 19, 2018. D) A sight gauge #133337 for +10 Recirculator in Engine Room #2 was mislabeled as #133338. This deficiency was last observed on June 20, 2018.
Recent events (2)
- — I (O) $8638
- — Z (S) $8638
More inspections at Tyson Foods, INC.
View Tyson Foods, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343027140.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.