PHILADELPHIA, PA —
OSHA Inspection: HIGH INNOVATIONS CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HIGH INNOVATIONS CORPORATION in 802 SAMSON ST, PHILADELPHIA, PA 19106 (NAICS 238160). OSHA activity number 343031365.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HIGH INNOVATIONS CORPORATION
- Site address
- 802 SAMSON ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19106
- Mailing
- 47 FITZRANDOLPH AVE., HAMILTON, NJ 08610
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.25 A
- Issued
- Jun 21, 2018
- Abate by
- Jun 27, 2018
- Penalty
- Initial $3,659 · Current $3,659
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: (a) 8th & Samson, Philadelphia - On or about 2/26/18, the employer allowed construction debris to accumulate on and in the stairway access to the roof, exposing employees to slip, trip & fall hazards.
Recent events (1)
- — Z (S) $3659
1926.404 B01 I
- Issued
- Jun 21, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $3,049 · Current $3,049
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: (a) 8th & Samson, Philadelphia - On or about 2/26/18, an extension cord and compressor were not grounded or protected with a GFCI, exposing employees to electrical hazards.
Recent events (1)
- — Z (S) $3049
1926.404 F06
- Issued
- Jun 21, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) 8th & Samson, Philadelphia - On or about 2/26/18, an electric air compressor did not have a continuous path to ground, exposing employees to electrical hazards.
Recent events (1)
- — Z (S) $0
1926.405 A02 II C
- Issued
- Jun 21, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(C): Receptacles used on temporary wiring were not of the grounding type: (a) 8th & Samson, Philadelphia - On or about 2/26/18, receptacles used to supply power to equipment including but not limited to air compressors, were not of the grounding type, exposing employees to electrical hazards.
Recent events (1)
- — Z (S) $0
1926.405 G02 IV
- Issued
- Jun 21, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) 8th & Samson, Philadelphia - On or about 2/26/18, the power cord for an air compressor was not provided with strain relief, exposing employees to electrical hazards.
Recent events (1)
- — Z (S) $0
1926.502 F02 II
- Issued
- Jun 21, 2018
- Abate by
- Jun 27, 2018
- Penalty
- Initial $1,829 · Current $1,829
General-duty citation text
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface. (a) 8th & Samson, Philadelphia - On or about 2/26/18, the warning line system in use had flagged rope which was less than 34 inches from the walking working surface, exposing employees to fall hazards.
Recent events (1)
- — Z (S) $1829
1926.501 B10
- Issued
- Jun 21, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $8,536 · Current $8,536
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. (a) 8th & Samson, Philadelphia - On or about 2/26/18, employees performing roofing work were not provided with an adequate fall protection system, exposing employees to fall hazards. High Innovation Corporation was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1162921, citation number 1, item number 1 and was affirmed as a final order on 9/22/2016, with respect to a workplace located at 449 Hamilton St, Norristown, PA.
Recent events (1)
- — Z (R) $8536
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343031365.