Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TOP TIER REMODELING CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TOP TIER REMODELING CORPORATION in 150 S NICOLET ROAD, APPLETON, WI 54914 (NAICS 238310). OSHA activity number 343034054.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TOP Tier Remodeling Corporation — free Get an email when a new federal OSHA severe-injury report for TOP Tier Remodeling Corporation is published. One employer, no account, unsubscribe in one click.
Site address
150 S NICOLET ROAD
City
APPLETON
State
WI
ZIP
54914
Mailing
7547 W MONROE ST, NILES, IL 60714
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
6
Ownership type
A

7 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 4 exposed
Issued
Oct 17, 2018
Abate by
Nov 15, 2018
Penalty
Initial $1,037 · Current $1,037
29 CFR 1903.19(c)(1):   The employer failed to certify to OSHA (the Agency) that the following item(s) were abated within 10 calendar days after the abatement date:  a) Top Tier Remodeling Corporation, did not provide abatement certification within 10 calendar days after the abatement date on all the cited items.
Recent events (1)
  • — Z (O) $1037

1903.19 D01

Other-than-serious 1 instance 4 exposed
Issued
Oct 17, 2018
Abate by
Nov 15, 2018
Penalty
Initial $0 · Current $0
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.   Top Tier Remodeling Corporation, failed to provide documentation demonstrating the abatement method and completion of the cited items.
Recent events (1)
  • — Z (O) $0

1926.20 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 30, 2018
Abate by
Jun 5, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.20(b)(2):   It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with incident prevention; such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  On or about March 21, 2018 in a hotel at 150 S Nicolet Road in Appleton, the employer did not ensure that a competent person was performing frequent and regular inspections that could have recognized the electrical hazards associated with employees using lighting suspended from fixture wires without bulb protection, light switches and outlet receptacles without plate covers installed, and working around open light socket.
Recent events (1)
  • — Z (S) $3880

1926.405 A02 II E

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.  On or about March 21, 2018 in a hotel at 150 S Nicolet Road in Appleton, employees performing renovation job tasks were walking/working in the corridors using lighting with unprotected bulbs.
Recent events (1)
  • — Z (S) $0

1926.405 A02 II F

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension.  On or about March 21, 2018 in a hotel at 150 S Nicolet Road in Appleton, employees were walking/working in two corridors performing renovation job tasks using lighting suspended by the fixture wiring.
Recent events (1)
  • — Z (S) $0

1926.405 J01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.405(j)(1)(i): Live parts. Fixtures, lamp-holders, lamps, rosettes, and receptacles shall have no live parts normally exposed to employee contact. However, rosettes and cleat-type lamp-holders and receptacles located at least 8 feet (2.44 m) above the floor may have exposed parts.  On or about March 21, 2018 in a hotel at 150 S Nicolet Road in Appleton, employees were performing renovation job tasks in corridors and rooms without plate covers installed on energized light switches and outlet receptacles.
Recent events (1)
  • — Z (S) $0

1926.416 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by de-energizing the circuit and grounding it or by guarding it effectively by insulation or other means.  On or about March 21, 2018 in a hotel at 150 S Nicolet Road in Appleton, employees were performing renovation job tasks in a corridor with an energized light sconce with an open socket.
Recent events (1)
  • — Z (S) $0

View TOP Tier Remodeling Corporation's full OSHA safety record →