OSHA Inspection: PATTISON METAL FAB, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PATTISON METAL FAB, INC. in 701 N 15TH STREET, BROKEN ARROW, OK 74012 (NAICS 332322). OSHA activity number 343036075.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pattison Metal FAB, INC. — free Get an email when a new federal OSHA severe-injury report for Pattison Metal FAB, INC. is published. One employer, no account, unsubscribe in one click.
Site address
701 N 15TH STREET
City
BROKEN ARROW
State
OK
ZIP
74012
Mailing
701 N 15TH STREET, BROKEN ARROW, OK 74012
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
18
Ownership type
A

5 citations on file for this inspection.

1910.178 L04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 6, 2018
Abate by
Jun 28, 2018
Penalty
Initial $2,514 · Current $1,508 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    On or about March 20, 2018, at the establishment forklift truck operators had not had refresher training every three years.  This exposed employees to struck-by hazards.
Recent events (2)
  • — I (S) $1508.4
  • — Z (S) $2514

1910.242 B

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 6, 2018
Abate by
Jun 14, 2018
Penalty
Initial $1,885 · Current $1,131 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i:    On or about July 25, 2013, and at times prior thereto, in shop areas employees were allowed to use compressed air nozzles for cleaning purpose which was not the type that would reduce the pressure to below 30 p.s.i.  The employees were exposed to skin and eye injury.
Recent events (2)
  • — I (S) $1131
  • — Z (S) $1885

1904.41 A02

Other-than-serious 1 instance 30 exposed
Issued
Jun 6, 2018
Abate by
Jul 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1904.41(a)(2): 29 CFR 1904.41(a)(2) Annual electronic submission of OSHA Form 300A Summary of Work-Related Injuries and Illnesses by establishments with 20 or more employees but fewer than 250 employees in designated industries. If your establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and your establishment is classified in an industry listed in appendix A to subpart E of this part, then you must electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form.  Pattison Metal Fab, Inc. located at 701 North 15th Street, Broken Arrow, OK 74012: On or about March 20, 2018, the employer failed during calendar year 2016, to electronically submit information from their OSHA Form 300A or equivalent by 07/01/2017. The establishment employed 20 employees and is classified 332322 during calendar year 2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 E01 II

Other-than-serious 1 instance 2 exposed
Issued
Jun 6, 2018
Abate by
Jun 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1)(ii): Markings were not provided on electrical equipment for voltage, current, wattage and other ratings as necessary:    On or about March, 20, 2018, in the sheet metal shop, an electrical panel and disconnect did not have marking to identify the voltage or other ratings of the panel, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 I

Other-than-serious 1 instance 2 exposed
Issued
Jun 6, 2018
Abate by
Jun 14, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i): The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1:    On or about March 20, 2018, and at times prior thereto, at the circuit breaker panel in the sheet metal shop a circuit breaker panel was observed blocked by a table.  This prevents employees from quick access of the panels when needed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Pattison Metal FAB, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343036075.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.