OSHA Inspection: FARMER BROTHERS COFFEE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FARMER BROTHERS COFFEE in 2543 WEST BELT DRIVE, COLUMBUS, OH 43228 (NAICS 424490). OSHA activity number 343048864.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Farmer Brothers Coffee — free Get an email when a new federal OSHA severe-injury report for Farmer Brothers Coffee is published. One employer, no account, unsubscribe in one click.
Site address
2543 WEST BELT DRIVE
City
COLUMBUS
State
OH
ZIP
43228
Mailing
1912 FARMER BROTHERS DRIVE, NORTHLAKE, TX 76262
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424490
Employees
8
Ownership type
A

7 citations on file for this inspection.

1910.26 A

Other-than-serious 1 instance 8 exposed
Issued
Jun 8, 2018
Abate by
Jul 13, 2018
Penalty
Initial $5,544 · Current $0 Reduced
29 CFR 1910.26: The employer must ensure that each dockboard used meets the requirements of this section.  The employer must ensure:    29 CFR 1910.26(a): Dockboards are capable of supporting the maximum intended load in accordance with �1910.22(b);     a. On or about March 29, 2018, at the loading dock, a piece of plywood was used to span a gap between the loading platform and the transport vehicle when loading and unloading.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5544

1910.26 D

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 8, 2018
Abate by
Jul 13, 2018
Penalty
Initial $9,239 · Current $5,544 Reduced
29 CFR 1910.26(d): (d) Measures, such as wheel chocks or sand shoes, are used to prevent the transport vehicle (e.g. a truck, semi-trailer, trailer, or rail car) on which a dockboard is placed, from moving while employees are on the dockboard;    a. On or about March 29, 2018, at the loading dock, the employer failed to ensure the use of wheel chocks or similar measures while employees loaded and unloaded transport vehicles.
Recent events (2)
  • — I (S) $5543.55
  • — Z (S) $9239

1910.151 C

Other-than-serious 1 instance 8 exposed
Issued
Jun 8, 2018
Abate by
Jul 13, 2018
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.       a. On or about March 29, 2018, at the forklift battery charging area where employees may be exposed to battery electrolyte, a corrosive material, while charging the forklift battery, there was no suitable facilities for flushing of the eyes within the work area for immediate emergency use.  An eye wash station was located on the opposite side of the warehouse with obstructed access.
Recent events (2)
  • — I (O) $0
  • — Z (S) $9239

1910.178 G02

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 8, 2018
Abate by
Jul 13, 2018
Penalty
Initial $9,239 · Current $5,544 Reduced
29 CFR 1910.178(g)(2): Facilities shall be provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries.   a. On or about March 29, 2018, in the warehouse forklift charging area, the battery charging apparatus was not protected from damage by powered industrial vehicles.
Recent events (2)
  • — I (S) $5543.55
  • — Z (S) $9239

1910.178 L01 II

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 8, 2018
Abate by
Jul 13, 2018
Penalty
Initial $9,239 · Current $5,543 Reduced
29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).   a. On or about March 29, 2018, the employer did not ensure each operator was trained on the safe operation of the Raymond, model EASI R35TT, stand-up forklift prior to being permitted to operate it.
Recent events (2)
  • — I (S) $5543.25
  • — Z (S) $9239

1910.303 G01

Serious Gravity 5 2 instances 8 exposed
Issued
Jun 8, 2018
Abate by
Jul 13, 2018
Penalty
Initial $9,239 · Current $5,543 Reduced
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.   a. On or about March 29, 2018, located on the West wall of the warehouse, an electrical panel that was used to supply power to the Western half of the facility did not have sufficient working space due to the forklift battery charging apparatus, a fan, and stored plywood obstructing access to the panel which did not allow for ready and safe operation of the electrical equipment.     b. On or about March 29, 2018, located on the East wall of the warehouse, an electrical panel that was used to supply power to the Eastern half of the facility did not have sufficient working space due to cleaning supplies, boxes, and miscellaneous equipment obstructing access to the panel which did not allow for ready and safe operation of the electrical equipment.
Recent events (2)
  • — I (S) $5543.25
  • — Z (S) $9239

1910.305 G01 IV A

Other-than-serious 1 instance 8 exposed
Issued
Jun 8, 2018
Abate by
Jul 13, 2018
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: As a substitute for the fixed wiring of a structure;    a.  On or about March 29, 2018, on the East side of the warehouse, a flexible cord was used as a substitute for fixed wiring to supply power to the service desk, thereby exposing the employees to electrical shock and fire hazards.