Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KWIK TRIP, INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of KWIK TRIP, INC in 1626 OAK STREET, LA CROSSE, WI 54603 (NAICS 311511). OSHA activity number 343048955.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kwik Trip, INC — free Get an email when a new federal OSHA severe-injury report for Kwik Trip, INC is published. One employer, no account, unsubscribe in one click.
Establishment
KWIK TRIP, INC
Site address
1626 OAK STREET
City
LA CROSSE
State
WI
ZIP
54603
Mailing
P.O. BOX 2107, LA CROSSE, WI 54602
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311511
Employees
650
Ownership type
A

5 citations on file for this inspection.

1910.119 D03 II

Serious Gravity 5 5 instances 8 exposed
Issued
Aug 30, 2018
Abate by
Sep 21, 2018
Penalty
Initial $7,853 · Current $4,320 Reduced
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.    On or about March 26, 2018, the employer did not document that the equipment associated with the anhydrous ammonia refrigeration system complied with recognized and generally accepted good engineering practices, such as but not limited to, ANSI/IIAR 2 - 2008 "Equipment, Design, and Installation of Closed-Circuit Ammonia Mechanical Refrigerating Systems".    a) The emergency eyewash/safety shower unit installation outside of the engine room was not readily accessible.    b) There was no signage for the meaning of each alarm near the visual and audible alarms outside the engine room.    d) The pressure relief devices from the evaporative condensers vented downwards towards the employee walking/working surfaces.    e) The pressure relief devices from the evaporative condensers were less than 15 feet above the adjacent grade.
Recent events (2)
  • — I (S) $4320
  • — Z (S) $7853

1910.119 F01

Serious Gravity 5 8 instances 8 exposed
Issued
Aug 30, 2018
Abate by
Sep 21, 2018
Penalty
Initial $7,853 · Current $4,320 Reduced
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and addressing at least steps for each operating phase, safe operating limits, safety and health considerations, and safety systems and their functions as outlined by this paragraph:    On or about March 26, 2018, the employer did not develop written operating procedures that provided clear instructions for safety conducting activities involved in each covered process, in that the operating procedures are missing valve identifiers, such as but not limited to, the operating procedures for the Swing Compressor (SC-01).
Recent events (2)
  • — I (S) $4320
  • — Z (S) $7853

1910.119 J02

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 30, 2018
Abate by
Sep 21, 2018
Penalty
Initial $7,853 · Current $4,320 Reduced
29 CFR 1910.119(j)(2): The employer did not establish written procedures to maintain the on-going integrity of process equipment:    On or about March 26, 2018, the employer did not establish written procedures for inspection and testing of the ammonia refrigeration equipment, such as but not limited to, compressor high pressure cutouts and compressor low pressure cutouts.
Recent events (2)
  • — I (S) $4320
  • — Z (S) $7853

1910.119 G03

Other-than-serious 5 instances 8 exposed
Issued
Aug 30, 2018
Abate by
Oct 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.119(g)(3): The employer did not prepare a record which contained the identity of the employee, the date of training, and the means used to verify that the employee understood the training.    On or about March 26, 2018, the employer did not prepare a record which contained the identity of the employee, the date of training, and the means used to verify that the employee understood the training for operation of the ammonia refrigeration system.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.151 C

Other-than-serious 1 instance 8 exposed
Issued
Aug 30, 2018
Abate by
Sep 21, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  On or about March 26, 2018, the employer did not have suitable facilities for quick drenching or flushing of the body in the falling film room where corrosive chemicals were handled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Kwik Trip, INC's full OSHA safety record →