LA CROSSE, WI —
OSHA Inspection: KWIK TRIP, INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KWIK TRIP, INC in 1626 OAK STREET, LA CROSSE, WI 54603 (NAICS 311511). OSHA activity number 343048955.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KWIK TRIP, INC
- Site address
- 1626 OAK STREET
- City
- LA CROSSE
- State
- WI
- ZIP
- 54603
- Mailing
- P.O. BOX 2107, LA CROSSE, WI 54602
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311511
- Employees
- 650
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.119 D03 II
- Issued
- Aug 30, 2018
- Abate by
- Sep 21, 2018
- Penalty
- Initial $7,853 · Current $4,320 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. On or about March 26, 2018, the employer did not document that the equipment associated with the anhydrous ammonia refrigeration system complied with recognized and generally accepted good engineering practices, such as but not limited to, ANSI/IIAR 2 - 2008 "Equipment, Design, and Installation of Closed-Circuit Ammonia Mechanical Refrigerating Systems". a) The emergency eyewash/safety shower unit installation outside of the engine room was not readily accessible. b) There was no signage for the meaning of each alarm near the visual and audible alarms outside the engine room. d) The pressure relief devices from the evaporative condensers vented downwards towards the employee walking/working surfaces. e) The pressure relief devices from the evaporative condensers were less than 15 feet above the adjacent grade.
Recent events (2)
- — I (S) $4320
- — Z (S) $7853
1910.119 F01
- Issued
- Aug 30, 2018
- Abate by
- Sep 21, 2018
- Penalty
- Initial $7,853 · Current $4,320 Reduced
General-duty citation text
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and addressing at least steps for each operating phase, safe operating limits, safety and health considerations, and safety systems and their functions as outlined by this paragraph: On or about March 26, 2018, the employer did not develop written operating procedures that provided clear instructions for safety conducting activities involved in each covered process, in that the operating procedures are missing valve identifiers, such as but not limited to, the operating procedures for the Swing Compressor (SC-01).
Recent events (2)
- — I (S) $4320
- — Z (S) $7853
1910.119 J02
- Issued
- Aug 30, 2018
- Abate by
- Sep 21, 2018
- Penalty
- Initial $7,853 · Current $4,320 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish written procedures to maintain the on-going integrity of process equipment: On or about March 26, 2018, the employer did not establish written procedures for inspection and testing of the ammonia refrigeration equipment, such as but not limited to, compressor high pressure cutouts and compressor low pressure cutouts.
Recent events (2)
- — I (S) $4320
- — Z (S) $7853
1910.119 G03
- Issued
- Aug 30, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(g)(3): The employer did not prepare a record which contained the identity of the employee, the date of training, and the means used to verify that the employee understood the training. On or about March 26, 2018, the employer did not prepare a record which contained the identity of the employee, the date of training, and the means used to verify that the employee understood the training for operation of the ammonia refrigeration system.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.151 C
- Issued
- Aug 30, 2018
- Abate by
- Sep 21, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about March 26, 2018, the employer did not have suitable facilities for quick drenching or flushing of the body in the falling film room where corrosive chemicals were handled.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Kwik Trip, INC
View Kwik Trip, INC's full OSHA safety record →
More inspections in this industry (NAICS 311511)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343048955.