LODI, NJ —
OSHA Inspection: ELVI MOLLA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ELVI MOLLA in 139 UNION STREET, LODI, NJ 07644 (NAICS 238130). OSHA activity number 343049011.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELVI MOLLA
- Site address
- 139 UNION STREET
- City
- LODI
- State
- NJ
- ZIP
- 07644
- Mailing
- 139 UNION STREET, LODI, NJ 07644
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.416 A01
- Issued
- Jul 5, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a-Building Exterior: Employees were observed exposed to electrocution hazards as ladder access was within 2 feet of energized secondary power which had not been de-energized. Condition noted on or about 03/20/2018.
Recent events (1)
- — Z (S) $3880
1926.451 E01
- Issued
- Jul 5, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. a-Ladder Jack Scaffold: An employee was observed exposed to fall hazards of approximately 16ft as a means of scaffold access was not utilized. Condition noted on or about 03/20/2018.
Recent events (1)
- — Z (S) $3880
1926.451 G01
- Issued
- Jul 5, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection. a-Ladder Jack Scaffold: An employee engaged in roofing activities from a ladder jack scaffold was exposed to fall hazards of approximately 16ft to the ground below as a means of fall protection was not utilized. Condition noted on or about 03/20/2018
Recent events (1)
- — Z (S) $3880
1926.501 B13
- Issued
- Jul 5, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system : a- Residential Roof: Employees while engaged in roofing activities were exposed to fall hazards of approximately 16ft to the ground below as a means of fall protection was not utilized. Condition noted on or about 03/20/2018
Recent events (1)
- — Z (S) $3880
1926.1053 B01
- Issued
- Jul 5, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing access. a- Residential Exterior: Employees were exposed to fall hazards of approximately 16ft to the ground below as a ladder used to access the roof whose side rails did not extend 3ft above the upper landing surface. Condition noted on or about 03/20/2018
Recent events (1)
- — Z (S) $3880
More inspections in this industry (NAICS 238130)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343049011.