Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AQUA AMERICAN, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AQUA AMERICAN, INC. in 1200 EAST BALTIMORE PIKE, MEDIA, PA 19063 (NAICS 221310). OSHA activity number 343049821.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aqua American, INC. — free Get an email when a new federal OSHA severe-injury report for Aqua American, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AQUA AMERICAN, INC.
Site address
1200 EAST BALTIMORE PIKE
City
MEDIA
State
PA
ZIP
19063
Mailing
1200 EAST BALTIMORE PIKE, MEDIA, PA 19063
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221310
Employees
7
Ownership type
A

1 citation on file for this inspection.

1910.134 D03 III B 2

Other-than-serious 1 instance 2 exposed
Issued
May 16, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 0640

29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not describe in the respirator program the information and data relied upon and the basis for the cartridge change schedule and the basis for the reliance on the data:  a. Chlorine Storage Room - The employer did not describe in the respirator program the information and data relied upon and the basis for the cartridge change schedule and the basis for reliance on the data.  During the connecting and disconnecting of one-ton chlorine containing cylinders, the employer required employees to wear 3M Versaflo TR-600 Powered Air Purifying Respirators (PAPR) equipped with TR-6530N Organic Vapor/Acid Gas (SD, HC, HF, Chlorine)/ HE cartridges. Observed On or About March 14, 2018
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343049821.