On , OSHA opened a planned safety inspection of PROGRESSIVE FRAMING LLC in 916 E. HAMPDEN AVE, AURORA, CO 80013 (NAICS 238160). OSHA activity number 343050332.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Progressive Framing LLC — free Get an email when a new federal OSHA severe-injury report for Progressive Framing LLC is published. One employer, no account, unsubscribe in one click.
Site address
916 E. HAMPDEN AVE
City
AURORA
State
CO
ZIP
80013
Mailing
12820 E. 13TH PLACE, AURORA, CO 80011
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 13, 2018
Abate by
May 2, 2018
Penalty
Initial $2,956 · Current $2,956
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  (a) On or about March 14, 2018, employees were exposed to flying objects while not using appropriate personal protective equipment necessary to protect them from the hazard.  Employees were observed using pneumatic nail guns without appropriate impact-resistant safety glasses while securing building wrap.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $2956

1926.451 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 13, 2018
Abate by
Apr 25, 2018
Penalty
Initial $5,174 · Current $5,174
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement:  a) On or about March 14, 2018, and at times prior, employees were exposed to fall hazards due to working on a pump-jack scaffold that did not have the pump jack brackets fixed at a plumb and level setting.  Employees were using a pump jack to work on surfaces at angles up to 35 degrees at the third story of a new multi-family residence.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $5174

1926.451 G01 VII

Serious Gravity 10 2 instances 2 exposed
Issued
Apr 13, 2018
Abate by
Apr 25, 2018
Penalty
Initial $5,174 · Current $5,174
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  (a)  On or about March 14, 2018, employees were exposed to fall hazards due to lack of a guardrail system, safety net system, or personal fall arrest system while engaged in residential construction activities more than 10 feet above a lower level.  Employees were observed using a plywood sheet balanced on the forks of a forklift to transport employees from the ground level to the third story.     (b) On or about March 14, 2018, employees were exposed to fall hazards due to lack of a guardrail system on the ends of a pump-jack scaffold used for residential construction activities more than 10 feet above a lower level. An employee was observed working on a pump-jack scaffold without end guards while installing housewrap on the third story. Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $5174

1926.1053 B01

Serious Gravity 1 1 instance 8 exposed
Issued
Apr 13, 2018
Abate by
May 2, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) On or about March 14, 2018, and at times prior, employees were exposed to fall from height hazards due to portable ladder side rails not extending at least 3 feet above the upper landing surface.  Employees used a portable ladder on the second story landing to access the third story.  At the time of inspection the ladder side rails extended approximately less than 6" above the upper landing surface.  Abatement note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $2217