BLUM, TX —
OSHA Inspection: DYNAENERGETICS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DYNAENERGETICS in 3580 HCR 1145 LOOP NORTH, BLUM, TX 76627 (NAICS 213112). OSHA activity number 343051744.
Where did this inspection happen?
- Establishment
- DYNAENERGETICS
- Site address
- 3580 HCR 1145 LOOP NORTH
- City
- BLUM
- State
- TX
- ZIP
- 76627
- Mailing
- 3580 HCR 1145 LOOP NORTH, BLUM, TX 76627
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.37 B02
- Issued
- Jul 16, 2018
- Abate by
- Aug 13, 2018
- Penalty
- Initial $2,968 · Current $1,781 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit". The employer did not ensure exit doors were equipped or identified with proper EXIT signs exposing employees to entrapment hazards: a) Exit door in the shoot room b) Exit door in the maintenance room
Recent events (2)
- — I (S) $1780.8
- — Z (S) $2968
1910.242 B
- Issued
- Jul 16, 2018
- Penalty
- Initial $2,968 · Current $1,781 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. In the gun shooting building, employees using compressed air for cleaning purposes that was not reduced to 30 p.s.i. The employees were exposed to eye and skin hazards.
Recent events (2)
- — I (S) $1780.8
- — Z (S) $2968
1910.134 C02 I
- Issued
- Jul 16, 2018
- Penalty
- Initial $617 · Current $370 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: Shape Charge, employees voluntarily wearing filtering face piece respirators were not provided Appendix D potentially exposing them to respiratory inhalation hazards.
Recent events (2)
- — I (O) $370.2
- — Z (O) $617
More inspections at Dynaenergetics