TULSA, OK —
OSHA Inspection: INTERNATIONAL CUSTOM CONTROLS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of INTERNATIONAL CUSTOM CONTROLS in 7835 S. 87TH W. AVE, TULSA, OK 74131 (NAICS 335313). OSHA activity number 343052122.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTERNATIONAL CUSTOM CONTROLS
- Site address
- 7835 S. 87TH W. AVE
- City
- TULSA
- State
- OK
- ZIP
- 74131
- Mailing
- P.O. BOX 1186, SAPULPA, OK 74067
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335313
- Employees
- 27
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.253 B04 III
- Issued
- May 10, 2018
- Abate by
- May 16, 2018
- Penalty
- Initial $3,880 · Current $2,328 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about March 27, 2018, oxygen cylinders and fuel-gas cylinders in storage were not separated by a minimum distance of 20 feet or by a noncombustible barrier with a fire-resistance rating of at least one-half hour. Employees were exposed to the hazard of fire and/or explosion.
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
1910.178 L02 II
- Issued
- May 10, 2018
- Abate by
- May 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. On or about March 27, 2018, the employer did not ensure that each powered industrial truck operator had completed training that consisted of a combination of formal instruction, practical training, and evaluation of operator's performance. Employees were exposed to the hazard of being struck by forklift and/or struck by falling load.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- May 10, 2018
- Abate by
- May 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: On or about March 27, 2018, shop area, the required working space around 480 volt electrical equipment was used for storage. Employees were exposed to the hazards associated with fire.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at International Custom Controls
View International Custom Controls's full OSHA safety record →
More inspections in this industry (NAICS 335313)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343052122.