AUBURN, AL —
OSHA Inspection: RAY'S COLLISION CENTER OF AUBURN, INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of RAY'S COLLISION CENTER OF AUBURN, INC in 130 E VETERANS BLVD, AUBURN, AL 36832 (NAICS 811121). OSHA activity number 343053161.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAY'S COLLISION CENTER OF AUBURN, INC
- Site address
- 130 E VETERANS BLVD
- City
- AUBURN
- State
- AL
- ZIP
- 36832
- Mailing
- 130 E VETERANS BLVD, AUBURN, AL 36832
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 11
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.253 B02 II
- Issued
- Apr 25, 2018
- Penalty
- Initial $2,513 · Current $2,513
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected area and were not secured to ensure that the cylinders would not be knocked over: (a) Welding area: On or about March 29, 2018 and at times prior thereto the employer exposed employees to the hazards of improperly stored compressed gas cylinders in that the cylinders were not secured to ensure that the cylinders would not be knocked over.
Recent events (1)
- — Z (S) $2513
1910.253 B04 III
- Issued
- Apr 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour (a) Welding area: On or about March 29, 2018 and at times prior thereto the employer exposed employees to fire hazards in that employees were allowed to walk and work in the same area where oxygen gas cylinders and acetylene gas cylinders were stored together.
Recent events (1)
- — Z (S) $0
1910.134 C01
- Issued
- Apr 25, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a)Painting area: On or about March 29, 2018 and at times prior thereto the employer failed to establish and implement a written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures for employees required the employer to use half face piece negative pressure respirators when spray painting.
Recent events (1)
- — Z (O) $0
1910.134 E01
- Issued
- Apr 25, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a)Painting area: On or about March 29, 2018 and at times prior thereto the employer failed to provide medical evaluation for respirator use to painting employees required to use half-mask negative pressure respirators during spray painting work at the paint booth.
Recent events (1)
- — Z (O) $0
1910.134 F02
- Issued
- Apr 25, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) Painting area: On or about March 29, 2018 and at times prior thereto the employer failed to fit test employees required to use tight fitting respirators prior to initial use of the respirators.
Recent events (1)
- — Z (O) $0
1910.134 K
- Issued
- Apr 25, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: (a)Painting area: On or about March 29, 2018 and at times prior thereto the employer failed to provide employees with comprehensive, understandable training. The employer required employees to use half face negative pressure tight fitting respirators when spray painting parts at the spray booth.
Recent events (1)
- — Z (O) $0
1910.134 K06
- Issued
- Apr 25, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a)Vehicle repair area: On or about March 29, 2018 and at times prior thereto the employer did not provide employees wearing respirators voluntarily with basic advisory information on respirators as presented in Appendix D of 29 CFR 1910.134.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 811121)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343053161.