WAXAHACHIE, TX —
OSHA Inspection: REFRIGERATION DESIGN TECHNOLOGIES
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of REFRIGERATION DESIGN TECHNOLOGIES in 1808 FM 66, WAXAHACHIE, TX 75167 (NAICS 333415). OSHA activity number 343056511.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REFRIGERATION DESIGN TECHNOLOGIES
- Site address
- 1808 FM 66
- City
- WAXAHACHIE
- State
- TX
- ZIP
- 75167
- Mailing
- P.O. BOX 622, WAXAHACHIE, TX 75168
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 50
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 C01
- Issued
- Aug 1, 2018
- Abate by
- Aug 29, 2018
- Penalty
- Initial $2,968 · Current $1,781 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: A written respiratory protection program was not established for employees wearing 3M half mask air purifying and Miller powered air purifying respirators during welding operations exposing employees to respiratory hazards.
Recent events (2)
- — I (S) $1780.8
- — Z (S) $2968
1910.134 E01
- Issued
- Aug 1, 2018
- Abate by
- Aug 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: In the production area, employees wearing 3M half face air purifying and Miller powered air purifying respirators during welding operations were not medical evaluated prior to initial use of the respirator were exposed to physiological hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1026 D01
- Issued
- Aug 1, 2018
- Abate by
- Aug 29, 2018
- Penalty
- Initial $2,968 · Current $1,781 Reduced
General-duty citation text
29 CFR 1910.1026(d)(1): General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section. The employer did not perform initial monitoring for employees welding on stainless steel. Employees were potentially exposed to chromium (VI), a skin and respiratory inhalation hazard.
Recent events (2)
- — I (S) $1780.8
- — Z (S) $2968
1910.1200 E01
- Issued
- Aug 1, 2018
- Abate by
- Aug 29, 2018
- Penalty
- Initial $2,968 · Current $1,781 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following. a) The employer had not developed a written hazard communication program for employees performing tasks such as, welding, grinding, cleaning and maintenance operations. Employees using products, such as, but not limited to zinc oxide, methyl ethyl ketone and chromium (VI) were potentially exposed to skin and respiratory inhalation hazards. b) The employer did not provide hazard communication training for employees performing tasks such as, welding, grinding, cleaning and maintenance operations. Employees using products, such as, but not limited to zinc oxide, methyl ethyl ketone and chromium (VI) were potentially exposed to skin and respiratory inhalation hazards.
Recent events (2)
- — I (S) $1780.8
- — Z (S) $2968
1910.132 D02
- Issued
- Aug 1, 2018
- Abate by
- Aug 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. At this establishment, the employer did not ensure a workplace hazard assessment was performed. Employees were potentially exposed to respiratory and skin irritation when performing tasks such as, but not limited to cleaning, welding and maintenance duties.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Refrigeration Design Technologies
View Refrigeration Design Technologies's full OSHA safety record →
More inspections in this industry (NAICS 333415)
More inspections in TX