Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PNP ROOFING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PNP ROOFING INC. in 601 EAST NASA PARKWAY, WEBSTER, TX 77598 (NAICS 238160). OSHA activity number 343057543.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PNP Roofing INC. — free Get an email when a new federal OSHA severe-injury report for PNP Roofing INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PNP ROOFING INC.
Site address
601 EAST NASA PARKWAY
City
WEBSTER
State
TX
ZIP
77598
Mailing
5815 LEEDALE ST, HOUSTON, TX 77016
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
A

3 citations on file for this inspection.

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 16, 2018
Abate by
May 3, 2018
Penalty
Initial $3,696 · Current $2,217 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    a)  At 601 East NASA Parkway, Webster, Texas, the working level of tubular welded frame scaffolding, approximately 12 feet above the ground, were not equipped with guardrails.
Recent events (2)
  • — I (S) $2217
  • — Z (S) $3696

1926.501 B10

Serious Gravity 5 1 instance 20 exposed
Issued
Apr 16, 2018
Abate by
May 3, 2018
Penalty
Initial $3,696 · Current $2,217 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:    a)  At 601 East NASA Parkway, Webster, Texas, employees installing laminate on a low slope roof with unprotected sides and edges, approximately 20 feet above the ground, were not protected from falling by any type of a fall protection system.
Recent events (2)
  • — I (S) $2217
  • — Z (S) $3696

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2018
Abate by
May 3, 2018
Penalty
Initial $3,696 · Current $2,217 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    a)  At 601 East NASA Parkway, Webster, Texas, the employer did not provide training to each employee exposed to fall hazards.
Recent events (2)
  • — I (S) $2217
  • — Z (S) $3696